MacroRAM Affordable Benchtop Raman Spectrometer
MacroRAM Benchtop Raman Spectrometer Video
How to set up your MarcoRAM
Spectroscopy on 60 seconds--MacroRAM Accessories and Probes
KnowItAll: Raman Spectral Searching LabSpec 6 Video

Benchtop Raman Spectrometer

MacroRAM™ is an easy-to-use macro Raman spectrometer for fast and reliable Raman analysis. Perfect for bulk analysis of solids, liquid solutions, powders, and gels, MacroRAM provides the flexibility and sensitivity to handle virtually any type of sample. With a compact and robust design including Class 1* laser safety, MacroRAM is ideal for use in most environments, from undergraduate teaching labs to industrial QC and manufacturing.

Powered by the industry-leading LabSpec 6 spectroscopy suite software, MacroRAM brings simplicity to macro Raman spectroscopy without compromising the ability to handle even the most challenging applications. It is ideal for confirming the identity and quality control of incoming raw materials, as well as for analyzing chemical composition, process monitoring, and assessing unknown substances. MacroRAM's durability and fixed internal setup ensure consistent and reproducible results over time, making it a reliable and robust choice for researchers, scientists, and industry professionals across such disciplines as pharmaceuticals, polymers & microplastics, forensics, wet chemistry, gemology, and other industries.

To facilitate the use of the MacroRAM in the undergraduate teaching laboratory setting, a series of educational labs are available. Designed to teach some of the most important concepts in Raman spectroscopy, such as identification, quantification, and vibrational chemistry, these educational labs can be used as is or tailored to fit the needs of any undergraduate laboratory. To learn more about these labs, please visit MacroRAM Educational Labs

事業部: Scientific
產品分類: Raman Spectroscopy
製造商: HORIBA Scientific

Download this macro Raman spectroscopy poster to hang in your lab

Featured Webinars

 

Featured Videos

MacroRAM Benchtop Raman Spectrometer Video

How To Set Up Your MacroRAM from HORIBA Video

scrollable

Video Player is loading.
Current Time 0:00
Duration 1:11
Loaded: 0%
Stream Type LIVE
Remaining Time 1:11
 
1x
    • Chapters
    • descriptions off, selected
    • subtitles off, selected
    • en (Main), selected

      Spectroscopy in 60 Seconds - MacroRAM Accessories and Probes Video

      Video Player is loading.
      Current Time 0:00
      Duration 1:11
      Loaded: 0.00%
      Stream Type LIVE
      Remaining Time 1:11
       
      1x
        • Chapters
        • descriptions off, selected
        • subtitles off, selected
        • en (Main), selected

        Spectroscopy in 60 Seconds - KnowItAll HORIBA Edition Video

        scrollable

        Presentation Video

        Video Player is loading.
        Current Time 0:00
        Duration 1:20
        Loaded: 0%
        Stream Type LIVE
        Remaining Time 1:20
         
        1x
          • Chapters
          • descriptions off, selected
          • subtitles off, selected
          • en (Main), selected

          Raman – it’s not just for experts anymore!

          No one has more experience in designing and manufacturing high quality Raman systems than HORIBA, from modular Raman microscopes to triple Raman spectrometers. The MacroRAM extends HORIBA’s Raman offerings to a bench-top Raman spectrometer for macroscopic measurements. Using superior optical components and design, the MacroRAM is an easy-to-use, yet highly sensitive instrument for both routine and complex Raman measurements.

          Features


          • Compact and robust design

          • User-friendly interface

          • Flexible sample handling

          • Best in class sensitivity

          • Safe operation

          • Affordable

          Hardware


          Laser

          The MacroRAM uses a 785 nm diode-pumped solid-state laser, with tunable output power from 7 mW to 450 mW and full width half maximum of 0.1 nm.  The power is controllable through LabSpec 6 software, scaling linearly from 0% (off) to 100% (full power).  The laser source is filtered through a narrow bandpass filter before being focused onto the sample in the sample compartment.  Raman signal is collected in the back scattered direction and filtered using an edge filter.

          Spectrograph

          The MacroRAM contains a fixed spectrograph for analysis of the resulting Raman signal.  It is equipped with a 685 gr/mm holographic grating for superior stray light rejection.  A spectrum is obtained by positioning a detector at the focal plane of the fixed spectrograph.  The dispersion is 10.3 nm/mm and provides a resolution of 8 cm-1 at 914 nm.

          Sample Compartment

          The sample compartment positions the sample at the focal point of the detection optics for optimal coupling to the spectrograph and detector.  A lens focuses light from the excitation laser to the sample, and the Raman signal is collected along the same path in a back-scattered Raman configuration directing the signal to the fixed spectrograph and detector.  The sample compartment accommodates various optional accessories.

          Detector

          Each MacroRAM contains a multichannel CCD detector to record a full spectrum of the resulting Raman signal from the sample.  It uses a back illuminated near-IR optimized Syncerity CCD cooled to -50°C for the highest available in-class sensitivity.  The use of the Syncerity CCD with the MacroRAM’s fixed spectrograph provides 3300 cm-1 of total spectral coverage (100 cm-1 to 3400 cm-1).  A correction file is stored to correct for wavelength dependencies of each optical component.  The files are created at HORIBA for every instrument and are automatically applied to data through the LabSpec 6 software.  Full details of the sensor can be found here.

          External Probes

          Each MacroRAM is equipped with the capability to connect an external probe for remote sample measurements.  The excitation source is passed through the sample compartment to a fiber where it is coupled to the LASER OUT port on the MacroRAM.  An FC/PC terminated fiber may then be connected from the LASER OUT port to an external probe.  The returning signal can then be connected using an FC/PC terminated fiber to the SIGNAL IN port on the MacroRAM.  An internal fiber then passes the signal to the fixed spectrograph and CCD detector for analysis of the Raman signal.  An external interlock, key switch, and safety shutter ensure safe operation when the laser is used in an external configuration.  To enable operation of the shutter, the key switch must be set to ENABLE.

          The external interlock can be used to connect to any number of additional safety measures, for example, a door switch.  The interlock is comprised of a two pin connector; continuity must be maintained between the two pins to enable laser output.  If continuity is interrupted, the shutter will automatically close, blocking the laser output.

          Software


          LabSpec 6 Spectroscopy Software

          The LabSpec 6 spectral software suite used on all the HORIBA Jobin Yvon analytical and research Raman spectrometer systems is now also available for modular Raman systems. It has been designed and written as a dedicated Raman spectroscopy package and offers many powerful capabilities not found in a basic spectroscopy software.

          Accessories


          HPLC Flow Cell

          With a sample capacity of 20 μL, this non-fluorescing fused silica cell is ideal for on-line monitoring of Raman samples. The cell maintains high sensitivity because it has a large aperture for collecting the excitation light to the sample and spontaneous Raman emission from the sample. The flat sides allow maximum throughput while keeping the scattering of the incident radiation to a minimum. In order to use this cell, the user must also have the thermostatted cuvette holder.

          Standard Quartz Cuvette

          With a 4-mL volume, this cell measures 10 mm × 10 mm in cross-section, and comes with a Teflon® stopper to contain volatile liquids.

          Reduced Volume Cuvette and Adapter

          Reduced volume cuvettes are available in 250 µL or 500 µL volumes. Each reduced volume cuvette requires an adapter to fit properly into the standard cuvette holder.

          Fused Silica Cuvette

          This 2-mL to 4-mL non-fluorescing fused silica cell can accept a magnetic stirrer, has a 10-mm path length, and includes a white Teflon® cap that prevents sample evaporation.

          Thermostatted Cuvette Holder

          The Thermostatted Cuvette Holder keeps a sample at a constant temperature from  -20°C to +80°C. From 5°C to +80°C the temperature is maintained with just water. Below 5°C the temperature is maintained by an ethylene glycol/water mixture pumped through an external circulating temperature bath (not included). The holder also includes a magnetic stirrer, enabling mixing of turbid or viscous samples.  For temperature measurements, the user must supply their own or purchase the Temperature Bath.

          Solid Sample Holder

          The Solid Sample Holder is designed for samples such as thin films, powders, pellets, microscope slides, and fibers.  The holder consists of a base with a dial indicating angle of rotation, upon which a bracket, a spring clip, and a sample block rest.  This holder comes standard with every MacroRAM.

          Cuvette Holder

          The Cuvette Holder is designed to hold standard 10 mm x 10 mm cuvettes for measurements of liquids.  With additional adapters, reduced volume cuvettes or smaller cuvettes can also be placed in the Cuvette Holder.  This holder comes standard with every MacroRAM.    

          SuperHead

          The SuperHead is a high efficiency remote Raman probe which enables in situ non-invasive chemical analysis to be undertaken.  The purpose of the SuperHead is to efficiently deliver the laser beam to the sample material, and to collect and filter the returning Raman signal.

          The SuperHead uses a single FC/PC terminated fiber for delivering the laser excitation and another FC/PC terminated fiber for signal collection. High efficiency filters incorporated within the probe provide effective laser and Raman filtering.

          The SuperHead can perform measurements in a non-contact/non-invasive mode or in an immersion mode, using specific accessories.

          Temperature Bath

          For studies of samples whose properties are temperature-dependent, use theTemperature Bath along with the Thermostatted Cuvette Holder (see above). The controller circulates fluids externally, with tubes leading to the sample chamber. The temperature range is from –20°C to +80°C. Sensor and all cables are included with the  Temperature Bath and it is available in a 110V and 220V version.

          External Probes

          Various external immersion and touch probes are available to add to the MacroRAM.  External probes can be easily connected to the MacroRAM for measurements outside of the sample compartment to accommodate larger or irregularly shaped samples. 

           

          Wavelength

          785 nm

          Laser Power

          7 mW – 450 mW

          Laser Safety

          Class 1, internal sample compartment; Class 3b, external probe

          Dispersion (nm mm-1)

          10.3

          Spectrograph f/#

          3.3

          Spectrograph Focal Length 

          115 mm

          Spectral Range

          100 – 3400 cm-1 (Stokes)

          Detector Type

          Syncerity Back illuminated NIR CCD

          Sensor Size

          2048 x 70

          Pixel size 

          14 µm

          Detector cooling

          -50°C

          Dynamic Range

          55,500:1

          CCD Dark Current (e-/pixel/s)

          0.05

          Spectral Resolution 

          8 cm-1 at 914 nm

          Dimensions  (W x D x H)

          432 mm (17”) x 432 mm (17”) x 381 mm (15”)

          Weight

          45 lbs (20.4 kg)

          Ambient Temperature Range

          15 – 30°C (59 – 86°F)

          Maximum Relative Humidity

          75%

          Power

          Universal AC single-phase input power; 100-240 V AC; line frequency 50 – 60 Hz

          Fuses

          One 5 x 20 mm IEC approved, 2.0 A, 250 V, time delay fuse

          Operating System

          Windows 7 or Windows 10 (32-bit or 64-bit)

          scrollable
          Following Epoxy Cure with Macroscopic Raman Analysis
          Following Epoxy Cure with Macroscopic Raman Analysis
          Because Raman spectroscopy provides information on molecular composition, it is an ideal tool for studying chemical reactions. In particular it has been used successfully for studying polymerization where the change often involves the disappearance of a carbon double bond (>C=C<) as the polymer chain is lengthened by the addition of a monomeric group. In this note we will be looking at epoxy cure which is a reaction that causes cross-linking during the polymerization process to form a solid with fixed three-dimensional geometry.
          Quantitative Analysis of Common Components in a Chemical Mechanical Polishing (CMP) Slurry Using Raman Spectroscopy
          Quantitative Analysis of Common Components in a Chemical Mechanical Polishing (CMP) Slurry Using Raman Spectroscopy
          In this application note, Raman spectroscopy is explored as an easier and more flexible technique for quantifying common components in a CMP slurry, such as benzotriazole and glycine, without any sample preparation or costly consumables.
          Quantitative Analysis Using Raman Spectroscopy in Pharmaceutical Applications
          Quantitative Analysis Using Raman Spectroscopy in Pharmaceutical Applications
          Raman spectroscopy is well known as a powerful analytical method for qualitative chemical analysis. Less well known is that under certain conditions Raman spectroscopy can also be an effective method for quantitative analysis. Here we demonstrate that capability for quantitative analysis under a variety of conditions, involving different solutes in a solution and solution mixtures, and its applications to pharmaceutical analysis such as content uniformity.
          Rapid Polymer Identification of Fishing Gear Using Raman Spectroscopy
          Rapid Polymer Identification of Fishing Gear Using Raman Spectroscopy
          Plastic pollution from fishing gear is a global problem that harms the environment. Recycling of damaged or abandoned fishing gear is one way of mitigating the issue, however the exact nature of the polymer must be known in order to identify the correct recycling stream. In this paper, the MacroRAM benchtop Raman spectrometer with remote BallProbe® is used to quickly identify plastics used in various gillnet samples. Raman spectroscopy is demonstrated to be an excellent technique for identifying not only different types of polymers, but also different variants within a polymer class and additives including pigments.

          展開

          留言諮詢

          如您有任何疑問,请在此留下詳細需求或問題,我們將竭誠您服務。

          * 這些欄位為必填項目。

          產品配件

          LabSpec 6 Spectroscopy Suite Software
          LabSpec 6 Spectroscopy Suite Software

          Enjoy a wonderful User eXperience with the unique features of Labspec 6 imaging and spectroscopy software!

          SERS Substrates
          SERS Substrates

          Ultrasensitive molecular detection

          SuperHead
          SuperHead

          Fiber probes: High Efficiency Raman sensors

          更多推荐

          HE Spectrograph
          HE Spectrograph

          High efficiency dedicated process Raman spectrometer for rugged and robust Raman monitoring.

          LabRAM Odyssey
          LabRAM Odyssey

          Confocal Raman & High-Resolution Spectrometer

          LabRAM Odyssey Semiconductor
          LabRAM Odyssey Semiconductor

          Photoluminescence and Raman Wafer Imaging

          LabRAM Soleil
          LabRAM Soleil

          Raman Spectroscope - Automated Imaging Microscope

          nanoGPS navYX
          nanoGPS navYX

          Collaborative Correlative Microscopy

          OEM Raman Miniature Probes
          OEM Raman Miniature Probes

          OEM Miniature Raman Systems and Components

          PoliSpectra® RPR for HTS
          PoliSpectra® RPR for HTS

          Rapid Raman Plate Reader – Multiwell Fast Raman screening

          Raman Fiber Probes
          Raman Fiber Probes

          Raman Spectrometers

          Raman Spectrometer - MINI-CCT+
          Raman Spectrometer - MINI-CCT+

          MINI-CCT+ Mini Raman Spectrometer

          UV Raman Spectrometer
          UV Raman Spectrometer

          for UV Raman spectroscopists

          XploRA™ PLUS
          XploRA™ PLUS

          MicroRaman Spectrometer - Confocal Raman Microscope

          展開

          Corporate