There is a local version available of this page. Change to the local version?
United States

EMIA-Expert

Carbon/Sulfur Analyzer
(Flagship High-Accuracy Model)

Your ultimate solution for reliable and accurate results

The EMIA-Expert Carbon/Sulfur Analyzer provides enhanced cleaning efficiency, user-friendly software, durability, operability and maintenance, resulting in efficient measurements. Its shortened cycle time accelerates the development and manufacturing speed. It includes the advanced accessories to enable even higher performance analysis, resulting in greater accuracy.

Typical Applications:
- Energy: Materials for lithium-ion battery, fuel cell, electrolyzer
- Electric parts
- Ceramics
- Semiconductor: Silicon, poly-silicon, GaN
- Steel and non-ferrous alloy (metallurgy): Iron, copper, nickel, aluminum, zinc, tungsten carbide
- Mineral: Cokes, lime stone, coal, silicone, rare-metal
- Others: Catalyst, rubber, carbon black, silica, cement


* For more entry-level applications, we also offer the EMIA-Pro Carbon/Sulfur Analyzer.

Сегмент: Scientific
Производитель: HORIBA, Ltd.

Greater Accuracy

Proven NDIR Gas Detection Technology

The EMIA-Expert is capable of measuring the concentration of Carbon and Sulfur in samples using the infrared method, which involves combustion in an induction furnace. HORIBA's proven Non-Dispersive Infrared (NDIR) measurement capabilities optimize its range for carbon, from 0.6 ppm to 10.0%, and for sulfur, from 0.6 ppm to 1.0%. The instrument is also equipped with a unique CO detector, and is suitable for a wide range of inorganic materials due to its versatility.

Please also refer the Measurement Principle page for the details.

 

Standard Accessories for EMIA-Expert

  • Purifier Unit for carrier gas (for C Analysis) - Enables measurement of ultra-low carbon concentration with high accuracy by eliminating hydrocarbon impurities in the carrier gas.
  • Heating Filter Unit (for S Analysis) - When samples are moist or generate water during analysis, a slight error can occur in sulfur analysis because the evolved water absorbs the SO2 gas. To prevent the absorption of SO2 by moisture and ensure highly accurate sulfur analysis, the heating filter unit can be used.

 


 

Improved Measurement and Maintenance Efficiency

Substantial Reduction in Maintenance

Along with the EMIA-Expert's cleaning feature, HORIBA has developed a robust design with fewer components for more reliable use and less service requirements.

 

The latest innovations have enabled the cleaning time for the EMIA Series to be typically half that of our conventional models (patent applied for*). Additionally, the structure around the combustion area has been designed to be as simple as possible, allowing for quick and intuitive maintenance. No specialized skills or knowledge required for maintenance work.

 

Flat design around the crucible stand    

 

The cleaning efficiency of the EMIA Series instruments has been significantly improved compared to our conventional Carbon/Sulfur analyzers with the use of a unique automatic cleaning mechanism (patent applied for*). This allows users to repeat measurements up to 200 times**, with reduced time required for maintenance and cleaning, without sacrificing measurement accuracy.

* JP6063582, US10379017, EP3064938, ZL201480058824.2, IN351227, JP6605807, US9778148, EP3037814 and ZL201510971175.1
** Number of repeatable measurements may vary depending on the sample and measurement conditions.

 

Before measurement                After 200 measurements

Video Player is loading.
Current Time 0:00
Duration 0:00
Loaded: 0%
Stream Type LIVE
Remaining Time 0:00
 
1x
    • Chapters
    • descriptions off, selected
    • subtitles off, selected
    • en (Main), selected

       

      High Throughput

      The EMIA Series can complete one measurement cycle, measurement-display result-cleaning, in 70 seconds (i.e. about 50 samples/hour).

       

      Flexible Upgrade after Installation

      Customers can expand the functionality of the system at any time, even after installation, to meet their changing needs. Additional options include:

      • Auto Sampler Unit - Able to accommodate up to 20 positions.
      • Halogen Trap Unit - Helps remove halogen elements in the sample to prevent damage to the device.

       


       

      More Intuitive Software for Easy Operation

      Advanced Operation Software

      The EMIA Series features its own proprietary operating software, which has been designed with a focus on ease of use, optimizing layout, operating menus, and functions for enhanced user-friendliness.

       

      Enhanced Operator Assistance

      Additionally, the software includes a self-diagnostic monitoring feature to assess the status of connected devices, an alarm function, and three navigators to recommend the most suitable conditions for samples, troubleshoot errors, and alert users to perform maintenance. These features improve daily operation and ensure efficient analysis.

      Video Player is loading.
      Current Time 0:00
      Duration 0:00
      Loaded: 0%
      Stream Type LIVE
      Remaining Time 0:00
       
      1x
        • Chapters
        • descriptions off, selected
        • subtitles off, selected
        • en (Main), selected

          *The user interface and functionalities of the software for this system are the same with those of EMIA-Pro.

          ContentsEMIA-Expert
          Required sample amount1g ± 0.1g
          Typical Meas. time70 seconds/cycle
          CarbonMeas. Range (m/m)0.6 ppm - 10.0%
          Blank accuracyσn-1≦ 0.3 ppm
          SulfurMeas. Range (m/m)0.6 ppm - 1.0%
          Blank accuracyσn-1 ≦ 0.3 ppm
          Sample meas. AccuracyCarbonσn-1 ≦ 0.3 ppm(less than 20 ppm) 
          σn-1 ≦ 1.0 ppm or RSD≦0.5%(more than 20 ppm)
          Sulfurσn-1 ≦ 0.3 ppm(less than 20 ppm) 
          σn-1 ≦ 1.0 ppm or RSD≦0.75%(more than 20 ppm)
          UtilityCarrier gasOxygen
          (Purity; 99.5%, Pressure; 0.3-0.33 MPa)
          Operation gasNitrogen
          (Purity; 99.5%, Pressure; 0.35-0.38 MPa)
          Power200/220/240V, 50/60Hz, 5kVA
          DimensionsMain unit*500(W) x 725(D) x 710(H) mm
          Purifier unit160(W) x 560(D) x 512(H) mm
          MassMain unitapproximately 134 kg
          Purifier unitapproximately 21 kg
          Data processing and operationUSB data communication with PC Windows 8.1
          Touch panel or Key board and mouse operation
          Model nameEMIA-20E: Carbon/Sulfur
          EMIA-21E: Carbon
          EMIA-22E: Sulfur
          scrollable

          Note) "ppm" is equal to mg/kg.

          *Except piping parts, projection parts (D:79mm) and flow meter on the back side.


          Schematics


          Accessories

          Crucible Pre-heating Unit

          The crucible pre-heating unit; FK-100 with automatic transportation function to heat a ceramic cruible at 1100 degree in 10min. before analysis.

          Autosampler

          Automation crucible loading and disposing unit. Up to 20 pcs of crucible are available to be set. Click here for more information of automation options.

          Consumables

          Ceramic crucible

          Low carbon blank and high dimension tolerance for high precision analysis.

          Accelerators

          High-purity materials which support stable analysis: Tungsten(W), Tin(Sn), Copper(Cu), Iron(Fe)

          Measurement of Oxygen Deficiency in Lithium Manganate
          Measurement of Oxygen Deficiency in Lithium Manganate
          Spinel-type lithium manganate (LiMn2O4-σ) is said to change its discharge characteristics due to slight differences in composition caused by oxygen deficiency. The differences in the discharge characteristics of lithium manganate batteries are also observed in the particle size and crystal structure, but attention is also paid to the difference in the oxygen bonding ratio, as samples with less oxygen bonding have poorer discharge characteristics.
          Analysis of carbon and sulfur in catalysts in oil refining
          Analysis of carbon and sulfur in catalysts in oil refining
          Refineries are equipped with desulfurization units to remove sulfur from oil. The changes in Carbon and sulfur content in catalysts before and after the usage is very important to determine the efficiency and performance of developed catalyst. Therefore, a reliable quantitative analysis of carbon and sulfur is important.
          Oxygen, Nitrogen, and Carbon Analysis in Nuclear Fuels
          Oxygen, Nitrogen, and Carbon Analysis in Nuclear Fuels
          From the perspective of ensuring energy security and reducing CO2 emissions, the use of nuclear energy is attracting worldwide attention. A joint declaration was also released by 25 countries setting forth a cooperation policy toward the ambitious goal of tripling the world's nuclear power generation capacity by 2050 compared to 2020 levels. The safety of nuclear fuel as well as the improvement of fuel performance is extremely important, and the content of oxygen, nitrogen, and carbon must be strictly controlled in nuclear material performance.
          Analysis of ultra-trace amounts of sulfur in metal
          Analysis of ultra-trace amounts of sulfur in metal
          As the steel materials are becoming more sophisticated, such as natural gas or crude oil pipeline, sulfur content is recommended below 0.5 ppm. Hence, more accurate ultra-trace amount sulfur analysis is required. Analysis of trace amount of sulfur in steel materials can be done quickly with the conventional combustion-infrared absorption method, but the problem is that the sensitivity of the detector is insufficient and it can not be measured.
          Purity Analysis in Precious Metal Recycling
          Purity Analysis in Precious Metal Recycling
          While precious metals such as Au, Ag, Pt, and Pd are finite materials, they are essential for electronic components and functional materials. Therefore, it is important to separate and extract the necessary precious metals from the final products and recycle them as high-purity precious metals in order to secure resources and reduce costs. Impurities, which must be controlled, include light elements such as carbon, sulfur, oxygen, and nitrogen. For example, Au (gold) used in electronic devices must be at least 99.999% pure.
          Quantitative analysis of carbon contained in bone substitute material
          Quantitative analysis of carbon contained in bone substitute material
          Can we accurately and quickly measure the amount of carbon contained in the material?
          Measurement of Carbon and Sulfur in Cement
          Measurement of Carbon and Sulfur in Cement
          This application note describes the method and conditions to use with the EMIA 820V C/S analyzer to measure cement.
          Measurement of Sulfur in Rubber
          Measurement of Sulfur in Rubber
          Sulfer is added in the natural rubber to produce plastic materials. However, it is important to measure the sulfer contained in the rubber to define the chemical and mechanical properties of the final product.
          Measurement of Carbon in Ferrosilicon
          Measurement of Carbon in Ferrosilicon
          Ferrosilicon is added as a deoxidant and as an alloying element to steel, that require a special low carbon content. The Low Carbon in Ferrosilicon decreases the electrical conductivity and magnetostriction of electrical steels.
          Measurement of Carbon and Sulfur in Copper
          Measurement of Carbon and Sulfur in Copper
          Copper in reddish metal, it is malleable, ductile and an extremely good conductor of both heat and electricity. Copper metal is widely used for electrical wiring, water piping, and corrosion resistant parts, either pure or in alloy such as brass and bronze. Carbon and Sulfur are considered as impurities, so it is important to measure and check the Copper purity.
          Measurement of Carbon and Sulfur in Titanium Oxide
          Measurement of Carbon and Sulfur in Titanium Oxide
          Titanium oxide are used primarily in the production of paints and plastics and are also used in paper, priniting inks, cosmetics, textiles and food stuffs.
          Carbon Analysis: Organic and Inorganic Carbon in Soils
          Carbon Analysis: Organic and Inorganic Carbon in Soils
          The aim of this application note is to explain the determination of organic and inorganic carbon in soils and how to prepare samples to eliminate inorganic carbon (carbonates) in these soils.

          Подробнее

          Запросить информацию

          У вас есть вопросы или пожелания? Используйте эту форму, чтобы связаться с нашими специалистами.

          * Эти поля обязательны для заполнения.

          Related products

          EMGA-921
          EMGA-921

          Hydrogen Analyzer

          EMGA-Expert
          EMGA-Expert

          Oxygen/Nitrogen/Hydrogen Analyzer
          (Flagship High-Accuracy Model)

          EMGA-Pro
          EMGA-Pro

          Oxygen/Nitrogen Analyzer (Entry Model)

          EMIA-Pro
          EMIA-Pro

          Carbon/Sulfur Analyzer (Entry Model)

          EMIA-Step
          EMIA-Step

          Carbon/Sulfur Analyzer (Tubular Electric Resistance Heating Furnace Model)

          GD-Profiler 2™
          GD-Profiler 2™

          Pulsed-RF Glow Discharge Optical Emission Spectrometer

          LabRAM Odyssey
          LabRAM Odyssey

          Confocal Raman & High-Resolution Spectrometer

          LabRAM Soleil
          LabRAM Soleil

          Raman Spectroscope - Automated Imaging Microscope

          SLFA-60
          SLFA-60

          X-ray Fluorescence Sulfur-in-Oil Analyzer

          SLFA-6000
          SLFA-6000

          X-ray Fluorescence Sulfur-in-Oil Analyzer

          XploRA™ PLUS
          XploRA™ PLUS

          MicroRaman Spectrometer - Confocal Raman Microscope

          XPLORER-NS*
          XPLORER-NS*

          Total Nitrogen and Sulfur Analyzer

          XPLORER-TX/TS*
          XPLORER-TX/TS*

          Total Halogen and Sulfur Analyzer

          Подробнее

          EMIA-Pro
          EMIA-Pro

          Carbon/Sulfur Analyzer (Entry Model)

          EMIA-Step
          EMIA-Step

          Carbon/Sulfur Analyzer (Tubular Electric Resistance Heating Furnace Model)

          SLFA-20
          SLFA-20

          X-ray Fluorescence Sulfur-in-Oil Analyzer

          51 серия
          51 серия

          Взрывозащищенный газоанализатор

          AP-380 Series
          AP-380 Series

          Air Quality Monitor

          APCA-370
          APCA-370

          Газоанализатор для измерения диоксида углерода в атмосферном воздухе

          APMA-370
          APMA-370

          Газоанализатор монооксида углерода в атмосферном воздухе

          BE-150
          BE-150

          OEM gas (CO/HC) analyzer

          BE-220FSD
          BE-220FSD

          OEM gas (NO) analyzer

          EMGA-921
          EMGA-921

          Hydrogen Analyzer

          EMGA-Expert
          EMGA-Expert

          Oxygen/Nitrogen/Hydrogen Analyzer
          (Flagship High-Accuracy Model)

          EMGA-Pro
          EMGA-Pro

          Oxygen/Nitrogen Analyzer (Entry Model)

          EMIA-Pro
          EMIA-Pro

          Carbon/Sulfur Analyzer (Entry Model)

          EMIA-Step
          EMIA-Step

          Carbon/Sulfur Analyzer (Tubular Electric Resistance Heating Furnace Model)

          ENDA-7000 Series
          ENDA-7000 Series

          Stack Gas Analyzer

          GA-370
          GA-370

          Монитор следовых газов

          GI-700 series
          GI-700 series

          Stack Gas Analyzer

          IR-300
          IR-300

          Vapor Concentration Monitor

          IR-400
          IR-400

          High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

          LO-300
          LO-300

          Laser scanning oil film detector

          MEXA-1300R
          MEXA-1300R

          Motor Exhaust Gas Analyzer

          MEXA-584L
          MEXA-584L

          Automotive Emission Analyzer

          OBS-ONE GS Unit
          OBS-ONE GS Unit

          On-board Emissions Measurement System

          OBS-ONE-XL (IRLAM)
          OBS-ONE-XL (IRLAM)

          On-board NH3/N2O Measurement System for real-world driving

          OCMA-500
          OCMA-500

          Анализатор нефтепродуктов

          OCMA-550
          OCMA-550

          Анализатор нефтепродуктов

          PG-300 series
          PG-300 series

          Portable Gas Analyzer

          PLGA-1000
          PLGA-1000

          Промышленный лазерный газоанализатор

          TCA-5000
          TCA-5000

          Hydrogen Gas Analyzer

          TX-100
          TX-100

          Tunable Laser Gas Analyzer

          серия AP-370
          серия AP-370

          Газоанализаторы загрязнения атмосферного воздуха

          серия ENDA-5000
          серия ENDA-5000

          Система анализа дымовых газов

          Серия VA-5000 / VA-5000WM
          Серия VA-5000 / VA-5000WM

          Многокомпонентный газоанализатор

          Подробнее

          Corporate