TX-100

Tunable Laser Gas Analyzer

TX-100 is HORIBA’s in-situ laser-based HCl analyzer with a probe type optical system. The TX-100 is suitable for monitoring HCl concentrations in incineration plant flue gas streams and for the control of HCl removal processes.

Division: Combustion
Manufacturing Company: HORIBA, Ltd.

Probe type optical system

  • Both laser and receiver are installed at the same side of the stack

  • Just one flange installation is sufficient for the setup

  • Easy replacement to an existing analyzer with no additional work

  • The stabilized optical axis provides excellent performance

  • Continuous moisture correction function supports high accuracy measurement

 

HORIBA’s original calibration mechanism


TX-100 implements calibration without any disruption to the facility’s operations. The zero point can be checked automatically and the signals are kept in stable condition over long term
(US patent No. 8934101; China patent No. ZL201280039440.7; patent applied for Japan, Europe)

 

<Measurement> Zero point checking and measurement are conducted alternately

Zero point checking mode
Zero point checking is carried out while the prism is inserted into the optical path at fixed intervals.

 

Measurement mode
In measurement mode, the prism moves upward and leaves the optical path

 

<Calibration> Calibration is conducted after span gas is filled in the calibration cell
Gas calibration is completed leaving the probe attached in the stack. 

 

Data management for the TX-100 can be selected from various components; Analyzer’s display, HMI (Human Machine Interface) unit, or from PC-HMI software

Analysis unit display
Basic display to confirm and control information such as equipment status, gas status and comunication status. 

 

HMI unit (option)
A touch panel screen that can set and confirm concentration, transmittance, trend graph, maintenance info, alarm status, etc.

 

PC-HMI (software)
PC-HMI is a software that includes almost the same function as the software instaled in HMI unit.  Install this software in a PC or other devices to operate. Ethernet is available for data transmission between PC and TX-100.  
Free download available from our website. 

 

Related Industries
NameTunable Laser Gas Analyzer
ModelTX-100
Measurement targetHCl and H2O in process gas
Measurement componentHCl, or HCl and H2O simultaneous measurement
Measurement principle

Non Dispersive Infrared (NDIR)

Measurement typeProbe type
Laser classCLASS1(IEC60825-1: 2014)
Protection degreeIP65
Wetted materialsSUS316L、SUS304、BK7、FKM、PTFE、aluminum alloy
Tube connectionsRc1/8 (Tube of 8 mm O.D./6 mm I.D.)
External dimentions

Analyzer: Max: 358 (W) x 517 (D) x 453 (H) mm
Probe
Flange diameter (Max.):  Φ235 mm、 Length: 1500 mm
Probe diameter: Φ 89 mm

Weight

Analyzer: 19 kg
Probe: 20 kg

Flange specificationsJIS10K-100AFF、JIS5K-125AFF、ANSI 150 Lb 4BRF
Power supply voltageDC24V±10%
Power consumption90 W
DisplayLCD (128 × 64 dots), LED (3 units: Status display)
Display contentsGas concentration, transmission, process gas temperature, process gas pressure, system status, alarm information, system information (product serial no., output signal, IP address, optical path length, analyzer unit internal temperature)
CommunicationModbusTM/TCP
Analog input/output

Input:
Two channels (Process gas temperature, process gas pressure)
4 to 20 mA (isolated input)

Output:
Two channels (Process gas concentration*, transmission, process gas temperature, process gas pressure)
4 to 20 mA (isolated output) Max. load: 550 Ω

Digital input/output

Input:
One channel (External alarm) 
Non-voltage digital input (isolated input) 
Input open signal: 100 kΩ or more 
Input close signal: 200 Ω or less

Output:
Two channels (Warning/Calibration/Warm-up/Maintenance state/Fault)
Relay contact output (isolated output) Max. 24 V, 1 A at each terminal
scrollable

*You can select either fixed value or real time HCl correction using H2O concentration.
-Modbus is a trademark of Schneider Electric Inc.
-Consult HORIBA if special probe length is required.

 

Performance

Measurement component

HCl, H2O

Measurement range (250℃、101.3kPa)

HCl: 0-50,100,200,300,400,500 ppm*1

H2O: 0-50 vol%

Measured optical path length2m
Repeatability

HCl: +/- 1.0% F.S.

H2O: +/- 2.0% F.S.

Linearity

HCl: +/- 1.0% F.S.

H2O: +/- 2.0% F.S.

Zero drift

+/- 2.0% F.S. / 6 months

Span drift+/- 2.0% F.S. / 6 months
Data update cycleApprox. 2sec
Recommended Calibration cycle6 months
Calibration methodHCl: Manual calibration using gas cell
H2O: Factory calibration*2
Interference

+/- 2.0% F.S.
Gas conditions (at standard process gas condition range)

Warm-up time3hours
scrollable

*1: Select a measurement range.
*2: You can adjust the H2O indicated value to the manual analysis value. Consult HORIBA for more details. 

 

 

Usage Conditions

Ambient temperature-20 ~ 55°C (no direct sun rays, radiant heat and heat conduction from flange)
Ambient humidityRelative humidity: 90% or less (no condensation)
DustAmbient criterion or less
Air purge

Instrument air (must not contain oil or mist; no dew formation)
Pressure: 0.2 to 0.25 MPa*

Air purge flow rate

60 L/min or more (depend on the process gas conditions)

VibrationAt 1 to 200 Hz, 1.96 m/s2 or less (excluding resonant frequency)
Process gas conditions

Temperature: 150 to 250°C

Pressure: 101.3 ± 10 kPa

Flow speed: 25m/s

Dust: 0.1mg/Nm3 or less

scrollable

* This value is supplied pressure to TX-100 main unit.  In case air passes through the purge unit, the pressure value at the purge unit is 0.2 to 0.9 MPa.

Solid Waste Combustors and Incinerators in Solid Waste Management and Remediation Services
Solid Waste Combustors and Incinerators in Solid Waste Management and Remediation Services

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

MESA-50
MESA-50

X선 형광 분석기

MESA-50K
MESA-50K

X선 형광 분석기

FTX-ONE-CL
FTX-ONE-CL

FTIR 배기 가스 분석기 희석 측정 타입

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR 배기가스 분석 측정 시스템 (직접 측정 방식)

IR-200
IR-200

Gas Monitor for Chamber Cleaning End Point Monitoring

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

MEXA-ONE
MEXA-ONE

배기 가스 측정 장치

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

레이저 분광 배기가스 측정 장치

OBS-ONE GS Unit
OBS-ONE GS Unit

차량 탑재형 배기가스 측정 장치

OBS-ONE IRLAM Unit
OBS-ONE IRLAM Unit

NH3/N2O 대응용 차량 탑재형 배기가스 측정 장치

Show More

EMGA-Expert
EMGA-Expert

산소/질소/수소 분석기

EMGA-Pro
EMGA-Pro

산소/질소/수소 분석기

EMIA-Expert
EMIA-Expert

탄소/황 분석기

EMIA-Pro
EMIA-Pro

탄소/유황 분석기

EMIA-Step
EMIA-Step

탄소/황 분석기 (인덕션 퍼니스 타입)

ENDA-7000 Series
ENDA-7000 Series

굴뚝 배출가스 분석장치

IR-200
IR-200

Gas Monitor for Chamber Cleaning End Point Monitoring

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

LO-300
LO-300

레이저 스캔 오일 필름 검출기

MEXA-ONE
MEXA-ONE

배기 가스 측정 장치

OBS-ONE GS Unit
OBS-ONE GS Unit

차량 탑재형 배기가스 측정 장치

OBS-ONE IRLAM Unit
OBS-ONE IRLAM Unit

NH3/N2O 대응용 차량 탑재형 배기가스 측정 장치

OCMA-500
OCMA-500

폐수 오일 측정기

OCMA-550
OCMA-550

오일 농도 측정기

Show More

Corporate