There is a local version available of this page. Change to the local version?
United States

APMA-370

Ambient Carbon Monoxide Monitor

The APMA-370 is a device for continuously monitoring CO concentrations using a Non-dispersion cross modulation infrared analysis method. The APMA-370 employs an independent, internal dry-method sampling device to achieve the highest levels of sensitivity and accuracy. The dry method, due to its capability for continuously monitoring and instantaneously analyzing of gas in its unaltered state as well as its minimal maintenance requirements, has been a preferred method for monitoring the atmospheric pollution.

 

Division: Ambient
Manufacturing Company: HORIBA, Ltd.
Base product: AP-370 Series

• Cross-flow non-dispersive infrared detector; Low range: 0-5 ppm F.S.
• AS type (anti-shock) interference-compensating detector and purifier for reference gas.
• Reference gas purifier oxidizes CO to CO2 to eliminate interferences.
• Optics remain free of foreign matter with elimination of reflecting mirrors.

 

Principle

Cross flow modulation, non-dispersive infrared (NDIR) absorption technology

Application

CO in ambient air

Range

Standard ranges: 0-10/20/50/100 ppm; 0-5/10/20/50 ppm; auto range ~ manual range selectable; can be operated by remote switching.
Optional (measurable) ranges: 4 ranges selectable from 0-200 ppm, within 10 times range ratio; auto range ~ manual range selectable; can be operated by remote switching.

Repeatability

±1.0% of F.S.

Linearity

±1.0% of F.S.

Sample gas flow rate

Approx. 1.5L/min

Indication

Measured value, range, alarm, maintenance screen

Alarms

During AIC, zero calibration error, span calibration error, temperature error in catalyzer, etc.

On-screen messages are available in four languages

English, German, French, and Japanese

Input/output

• 0-1 V/0-10 V/4-20 mA, to be specified (2 systems: either (1) momentary value and integrated or (2) moving average value) 
• Contact input/output 
• RS-232C

Power

100/110/115/120/220/230/240 VAC, 50/60 Hz (to be specified)

Dimensions

430(W) x 550(D) x 221(H) mm

Mass

Approx. 16 kg

scrollable

** Certified to U.S. EPA Reference Method RFCA

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

FTX-ONE-CL
FTX-ONE-CL

FTIR 배기 가스 분석기 희석 측정 타입

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR 배기가스 분석 측정 시스템 (직접 측정 방식)

IR-200
IR-200

Gas Monitor for Chamber Cleaning End Point Monitoring

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

MEXA-ONE
MEXA-ONE

배기 가스 측정 장치

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

레이저 분광 배기가스 측정 장치

OBS-ONE GS Unit
OBS-ONE GS Unit

차량 탑재형 배기가스 측정 장치

OBS-ONE IRLAM Unit
OBS-ONE IRLAM Unit

NH3/N2O 대응용 차량 탑재형 배기가스 측정 장치

Show More

EMGA-Expert
EMGA-Expert

산소/질소/수소 분석기

EMGA-Pro
EMGA-Pro

산소/질소/수소 분석기

EMIA-Expert
EMIA-Expert

탄소/황 분석기

EMIA-Pro
EMIA-Pro

탄소/유황 분석기

EMIA-Step
EMIA-Step

탄소/황 분석기 (인덕션 퍼니스 타입)

ENDA-7000 Series
ENDA-7000 Series

굴뚝 배출가스 분석장치

IR-200
IR-200

Gas Monitor for Chamber Cleaning End Point Monitoring

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

LO-300
LO-300

레이저 스캔 오일 필름 검출기

MEXA-ONE
MEXA-ONE

배기 가스 측정 장치

OBS-ONE GS Unit
OBS-ONE GS Unit

차량 탑재형 배기가스 측정 장치

OBS-ONE IRLAM Unit
OBS-ONE IRLAM Unit

NH3/N2O 대응용 차량 탑재형 배기가스 측정 장치

OCMA-500
OCMA-500

폐수 오일 측정기

OCMA-550
OCMA-550

오일 농도 측정기

Show More