There is a local version available of this page. Change to the local version?
United States

IT-480 series

High-Accuracy Infrared Thermometers [Stationary type]

Industry Leading* High Accuracy Thermometer

IT-480 series are compact, stationary type infrared thermometers with industry-leading* accuracy, which enables measurement without damaging the object.
These infrared thermometers are suitable for industrial applications such as temperature control of various product lines, devices and plants.
Also, by connecting USB to a personal computer (PC) equipped with Windowsยฎ, IT-480 series can be widely used for laboratory and R&D.
IT-480 Data Acquisition Software is required to connect PC to IT-480 series. This software can be downloaded free of cost.

โ–ถ Thermometer Application Examples

*Resuts of 2024 in-house study

Division: Thermometer
Manufacturing Company: HORIBA, Ltd.

Our IT-480 series and IT-545 series are registered to Sustainable Technology Promotion Platform (STePP)of United Nations Industrial Development Organization (UNIDO) Investment and Technology Promotion Office, Tokyo (ITPO Tokyo)

(URL: http://www.unido.or.jp/en/activities/technology_transfer/technology_db/)

<Features>

  • High precision: Industryโ€™s highest precision standard thermometer.
  • Traceability: Adjustment/Calibration according to the Japanese national standards.
  • Product conformity according to various country standards: CE, WEEE/RoHs, FCC, KC, laser pointer related (PSC, FDA)
  • Application software: Provided for free of cost
     

โ–ถ Non-contact, non-destructive system allows measurement without damaging the products whether stationary, rotating or moving.
โ–ถ Industry-leading high accuracy and real-time response.
โ–ถ A wide measurement range. -50ยฐC to 1000ยฐC (IT-480F/480P)
โ–ถ Compact, lightweight design allows installation in various devices and production lines.
โ–ถ Allows flexible use. For R&D, experiments, confirmation before the installation of IT-480 etc.
    Easy to set and use anywhere.
    ใƒปUSB bus powered type, which requires no external power supply.
    ใƒปAvailable to mount on the camera tripods.
    Use of Data Acquisition Software (downloadable free of cost)
    ใƒปUp to 8 units of IT-480 can be connected to a Windowsยฎ PC by USB cable.
    ใƒปEasy to setup by Windowsยฎ PC, and collects temperature data

<Software Screen example-Device Setup>

<Software screen example-Data acquisition>

<Software>

IT-480 Data Acquisition Software "IT-480 Data Acquisition" is software dedicated to the radiation thermometer IT-480 series. Check/Change of Various settings, operation check and data acquisition are available for IT-480 connected to a personal computer via USB with "IT-480 Data Acquisition".
This IT-480 Data Acquisition software is freely downloadable.
Many other items, other than this software are also downloadable.

*To use IT-480 series without this software current output: 4 mA to 20 mA is also available.

Software requirements

โ€ข This software functions on PC or tablets installed with either the 32-bit or 64-bit version of Windows 7, Windows 8, Windows 8.1, and Windows 10.
โ€ข At least 1 GB of hard disk space is required to install this software.
โ€ข A screen resolution of at least 1280 dots X 800 dots (100% scaling ratio) is recommended.

Function

This software can be used to execute the following functions:
โ€ข Checking and changing settings
โ€ข Auto emissivity setting
โ€ข Current output test
โ€ข Measurement data collection (maximum of 8 units can be connected)
General-purpose communication software can also be used.

Downloadable items:

  • Instruction Manual for the IT-480
  • Data Acquisition Software "IT - 480 Data Acquisition"
    • 32 bit.zip
    • 64 bit.zip
    • User Manual for the IT-480 Data Acquisition
  • Virtual COM port driver for IT-480
    • driver.zip

    Serial communication with IT-480 is available with communication software such as "Tera Term" or a program created by a customer by installing the virtual COM port driver for IT-480 on the personal computer.
    Check/Change of Various settings and measurement value acquisition for IT-480 are available with serial communication.
    When only IT - 480 data collection software "IT - 480 Data Acquisition" is used, Installation of the virtual COM port driver is not required.

    • Reference Manual for the IT-480 Virtual COM Port Driver

    This software works on personal computers or tablets equipped with Windows 7, Windows 8, Windows 8.1, Windows 10 (32 bit, 64 bit). Operation check is done at factory.
    It does not guarantee the operation on all devices.

    Download

 

Related Industries

โ– IT-480S, IT-480L

TypeMicro-spot typeSpot type
ModelIT-480SIT-480L
Spectral response8ฮผm to14ฮผm
Measured temperature range-50โ„ƒ to 500โ„ƒ
OutputUSB (resolution = 0.1โ„ƒ)
Current (4 mA to 20 mA, resolution =0.24ฮผA, non-insulated)
Currnent output range-50โ„ƒ to 500โ„ƒ ๏ผˆfactory setting 0โ„ƒ to 500โ„ƒ๏ผ‰
Accuracyใ€”USB Outputใ€•
Within ยฑ(-8%rdg+1)โ„ƒ๏ผป-50โ„ƒ to 0โ„ƒ๏ผฝ
Within ยฑ1โ„ƒ๏ผป 0โ„ƒ to 200โ„ƒ๏ผฝ
Within ยฑ0.5%rdgโ„ƒ๏ผป200โ„ƒ to 500โ„ƒ๏ผฝ
ใ€”Current Outputใ€•
Difference from USB data is within ยฑ(0.1% output range )โ„ƒ
RepeatabilityWithin 0.5โ„ƒ
Response TimeCurrent output 0.14 s or less
(95% response, moving average count is 1.)
Measurement diameterฯ†3 mm/ distance 30 mmฯ†8 mm/ distance 100 mm
Temperature driftWithin ยฑ0.5โ„ƒ/โ„ƒ๏ผป-50โ„ƒ to 0โ„ƒ๏ผฝ
Within ยฑ0.25โ„ƒ/โ„ƒ๏ผป0โ„ƒ to 500โ„ƒ๏ผฝ
EmissivityFactory setting: 0.950
(Setting range is 0.100 to 1.999.)
Ambient temperature / humidityTemperature: 0ยฐC to 55ยฐC
Humidity: 35% to 85% (No condensation)
Power supplyUSB bus power /12 V DC to 24 V DC
Power consumption30 mA or less (at 24 V DC)
Material of the body caseAluminum
MassApprox. 95 g
(Body only. Excluding cable and metal brackets)
SightSetting gauge
scrollable

โ– IT-480N, IT-480W, IT-480F, IT-480P

TypeGeneral purpose typeNarrow view type
ModelIT-480N / IT-480W*1IT-480F / IT-480P*1
Spectral response8ฮผm to 14ฮผm
Measured temperature range-50โ„ƒ to 500โ„ƒ-50โ„ƒ to 1000โ„ƒ
OutputUSB (resolution = 0.1โ„ƒ)
 Current (4 mA to 20 mA, resolution =0.24ฮผA, non-insulated)
Currnent output range-50โ„ƒ to 500โ„ƒ ๏ผˆfactory setting 0โ„ƒ to 500โ„ƒ๏ผ‰-50โ„ƒ to 1000โ„ƒ ๏ผˆfactory setting 0โ„ƒ to 500โ„ƒ๏ผ‰
Accuracyใ€”USB Outputใ€•
Within ยฑ(-8%rdg+1)โ„ƒ
ใ€€๏ผป-50โ„ƒ to 0โ„ƒ๏ผฝ
Within ยฑ1โ„ƒ
ใ€€๏ผป 0โ„ƒ to 200โ„ƒ๏ผฝ
Within ยฑ0.5%rdgโ„ƒ
ใ€€๏ผป200โ„ƒ to 500โ„ƒ๏ผฝ
ใ€”Current Outputใ€•
Difference from USB data is within ยฑ(0.1% output range )โ„ƒ
ใ€”USB Outputใ€•
Within ยฑ(-8%rdg+1)โ„ƒ
ใ€€๏ผป-50โ„ƒ to 0โ„ƒ๏ผฝ
Within ยฑ1โ„ƒ
ใ€€๏ผป 0โ„ƒ to 200โ„ƒ๏ผฝ
Within ยฑ0.5%rdgโ„ƒ
ใ€€๏ผป200โ„ƒ to 1000โ„ƒ๏ผฝ
ใ€”Current Outputใ€•
Difference from USB data is within ยฑ(0.1% output range )โ„ƒ
RepeatabilityWithin 0.5โ„ƒWithin 1โ„ƒ๏ผป -50โ„ƒ to 0โ„ƒ๏ผฝ
Within 0.5โ„ƒ๏ผป 0โ„ƒ to 500โ„ƒ๏ผฝ
Within 1โ„ƒ๏ผป 500โ„ƒ to 1000โ„ƒ๏ผฝ
Response TimeCurrent output 0.14 s or less
(95% response, moving average count is 1.)
Measurement diameterฯ†72 mm/ distance 1000 mmฯ†35 mm/ distance 1000 mm
Temperature driftWithin ยฑ0.5โ„ƒ/โ„ƒ
ใ€€๏ผป-50โ„ƒ to 0โ„ƒ๏ผฝ
Within ยฑ0.25โ„ƒ/โ„ƒ
ใ€€๏ผป0โ„ƒ to 500โ„ƒ๏ผฝ
Within ยฑ0.5โ„ƒ/โ„ƒ
ใ€€๏ผป-50โ„ƒ to 0โ„ƒ๏ผฝ
Within ยฑ0.25โ„ƒ/โ„ƒ
ใ€€๏ผป0โ„ƒ to 500โ„ƒ๏ผฝ
Within ยฑ0.5โ„ƒ/โ„ƒ
ใ€€๏ผป500โ„ƒ to 1000โ„ƒ]
EmissivityFactory setting: 0.950
(Setting range is 0.100 to 1.999.)
Ambient temperature / humidityTemperature: 0ยฐC to 55ยฐC
Humidity: 35% to 85% (No condensation)
Power supplyUSB bus power / 12 V DC to 24 V DC
Power consumption30 mA or less (at 24 V DC, laser: OFF)
40 mA or less (at 24 V DC, laser: ON)
Material of the body caseAluminum
MassApprox. 95 g
(Body only. Excluding cable and metal brackets)
Approx. 115 g
(Body only. Excluding cable and metal brackets)
SightLaser (Class 1)*1
scrollable

*1) IT-480W and IT-480P are not equipped with the laser pointer

Improving the Safety of Transport by Crane Using Thermometer
Improving the Safety of Transport by Crane Using Thermometer

์ œํ’ˆ ๋ฌธ์˜

HORIBA์ œํ’ˆ์˜ ์ž์„ธํ•œ ์ •๋ณด๋ฅผ ์›ํ•˜์‹œ๋ฉด, ์•„๋ž˜์˜ ์–‘์‹์— ๋‚ด์šฉ์„ ์ž…๋ ฅ์„ ๋ถ€ํƒ๋“œ๋ฆฝ๋‹ˆ๋‹ค.

* ๋Š” ํ•„์ˆ˜์ž…๋ ฅํ•ญ๋ชฉ์ž…๋‹ˆ๋‹ค.

Related products

CS-620F
CS-620F

๊ด‘์„ฌ์œ ํ˜• ๊ณ ์˜จ ์ธ์‚ฐ ๋†๋„ ๋ชจ๋‹ˆํ„ฐ

CS-900
CS-900

๋น„์ ‘์ด‰ ํ™”ํ•™๋ฌผ์งˆ ๋†๋„ ๋ชจ๋‹ˆํ„ฐ

HC-200F
HC-200F

ํ˜„์žฅ์„ค์น˜ํ˜• ๋ถˆ์†Œ์ด์˜จ์ธก์ •๊ธฐ(4-Wire Transmission)

HC-300F
HC-300F

ํ˜„์žฅ์„ค์น˜ํ˜• ๋ถˆ์†Œ์ด์˜จ์ธก์ •๊ธฐ(2-Wire Transmission)

HD-200
HD-200

ํ˜„์žฅ์„ค์น˜ํ˜• ์šฉ์กด์‚ฐ์†Œ์ธก์ •๊ธฐ(4-Wire Transmission), ๋ฉค๋ธŒ๋ ˆ์ธํ˜•)

HD-200FL (Four-Wire Transmission, ๊ด‘ํ•™์‹)
HD-200FL (Four-Wire Transmission, ๊ด‘ํ•™์‹)

ํ˜„์žฅ ์„ค์น˜ํ˜• ์šฉ์กด ์‚ฐ์†Œ ์ธก์ •๊ธฐ

HD-300
HD-300

ํ˜„์žฅ์„ค์น˜ํ˜• ์šฉ์กด์‚ฐ์†Œ์ธก์ •๊ธฐ(2-Wire Transmission), ๋ฉค๋ธŒ๋ ˆ์ธ ํ˜•)

HD-480
HD-480

์šฉ์กด์‚ฐ์†Œ์ธก์ •๊ธฐ(4-Wire Transmission), ๋ฉค๋ธŒ๋ ˆ์ธ ํ˜•)

HD-960L
HD-960L

์ €๋†๋„ ์šฉ์กด ์‚ฐ์†Œ ๋ชจ๋‹ˆํ„ฐ

HD-960LR
HD-960LR

์šฉ์กด ์‚ฐ์†Œ ๋†๋„ ๋ชจ๋‹ˆํ„ฐ

HE-200C
HE-200C

ํ˜„์žฅ์„ค์น˜ํ˜• ์ „๊ธฐ์ „๋„๋„๊ณ„(4-Wire Transmission, ์ €๋†๋„์šฉ)

HE-200H
HE-200H

ํ˜„์žฅ์„ค์น˜ํ˜• ์ „๊ธฐ์ „๋„๋„๊ณ„(4-Wire Transmission, ๊ณ ๋†๋„์šฉ)

HE-200R
HE-200R

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ „๊ธฐ์ €ํ•ญ๊ณ„(4-Wire Transmission)

HE-300C
HE-300C

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ „๊ธฐ์ „๋„๋„๊ณ„ (2-Wire Transmission, ์ €๋†๋„์šฉ)

HE-300C-IS ( ๋ฐฉํญํ˜• )
HE-300C-IS ( ๋ฐฉํญํ˜• )

๋ฐฉํญํ˜• ์„ค์น˜ ํƒ€์ž… COND meter ( Low concentrtion )

HE-300R
HE-300R

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ „๊ธฐ์ €ํ•ญ๊ณ„(2-Wire Transmission)

HE-480C
HE-480C

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-Wire Transmission, ์ €๋†๋„์šฉ)

HE-480C-GC
HE-480C-GC

์นด๋ณธ ์„ผ์„œ ์ „๋„๋„๊ณ„ (์ €๋†๋„ํ˜•)

HE-480H
HE-480H

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-Wire Transmission,์ €๋†๋„์šฉ)

HE-480H-DC24V
HE-480H-DC24V

ํŒ๋„ฌ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-wire Transmitter , ๊ณ ์ „๋„๋„์šฉ)

HE-480R
HE-480R

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ €ํ•ญ๊ณ„(4-Wire Transmission)

HE-960CA
HE-960CA

๊ตฌ์—ฐ์‚ฐ ๋ชจ๋‹ˆํ„ฐ

HE-960CW
HE-960CW

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-Wire Transmission, 2์ฑ„๋„)

HE-960H-KOH
HE-960H-KOH

KOH ๋ชจ๋‹ˆํ„ฐ

HE-960H-TM-S
HE-960H-TM-S

๊ณ ์ •๋ฐ€ TMAH ๋†๋„ ๋ชจ๋‹ˆํ„ฐ

HE-960HC
HE-960HC

์นด๋ณธ ์„ผ์„œ ์ „๋„๋„๊ณ„ (๊ณ ๋†๋„ํ˜•)

HE-960HI
HE-960HI

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-Wire Transmission, ๊ด‘์—ญ์šฉ)

HE-960LC
HE-960LC

์นด๋ณธ ์„ผ์„œ ์ „๋„๋„๊ณ„

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

ํ‰ํƒ„ ์นด๋ณธ ์„ผ์„œ ์ „๋„๋„๊ณ„

HE-960RW
HE-960RW

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ €ํ•ญ๊ณ„(4-Wire Transmission, 2์ฑ„๋„)

HE-960RW-GC(W)
HE-960RW-GC(W)

2-์ฑ„๋„ ์ €ํ•ญ๋ฅ ๊ณ„

HO-480
HO-480

ํŒจ๋„ ์žฅ์ฐฉํ˜• ORP ๋ฏธํ„ฐ (4-Wire Transmission)

HP-200 (Four-Wire Transmission)
HP-200 (Four-Wire Transmission)

ํ˜„์žฅ ์„ค์น˜ํ˜• pH Meter

HP-300
HP-300

ํ˜„์žฅ ์„ค์น˜ํ˜• pH๋ฏธํ„ฐ (2-Wire Transmission)

HP-480
HP-480

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH๋ฏธํ„ฐ (4-Wire Transmission)

HP-480PL
HP-480PL

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, ํŽ„์Šค ๋น„๋ก€ ์ œ์–ด)

HP-480TP
HP-480TP

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, ์‚ฐ์—…์šฉ ์‹œ๋ถ„ํ•  ๋น„๋ก€์ œ์–ด)

HP-960FTP
HP-960FTP

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, 4 ํฌ์ธํŠธ ์•Œ๋žŒ, ์‹œ๋ถ„ํ•  ๋น„๋ก€ ์ œ์–ด)

HR-200
HR-200

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ž”๋ฅ˜์—ผ์†Œ ์ธก์ •๊ธฐ (4-Wire Transmission, Water flow beads)

HR-200RT
HR-200RT

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ž”๋ฅ˜ ์—ผ์†Œ ์ธก์ •๊ธฐ (4-Wire Transmission, Rotating Type)

HR-480
HR-480

์ž”๋ฅ˜ ์—ผ์†Œ ์ธก์ •๊ธฐ (4-Wire Transmission)

LAQUA PH210
LAQUA PH210

Handheld pH/ORP/Temperature Meter

TW-100
TW-100

์ž๋™ ์ˆ˜์งˆ ์ธก์ •์žฅ์น˜

TW-150
TW-150

Online Water Quality Monitor (๊ณต์ • ์ˆ˜์งˆ ์ธก์ • ์‹œ์Šคํ…œ)

U-50 Series
U-50 Series

๋‹คํ•ญ๋ชฉ ์ˆ˜์งˆ ์ธก์ •๊ธฐ

UP-100
UP-100

๋งˆ์ดํฌ๋กœ ๋ณผ๋ฅจ pH ๋ชจ๋‹ˆํ„ฐ

Show More