There is a local version available of this page. Change to the local version?
United States

APSA-370

Ambient Sulfur Dioxide Monitor

The APSA-370 is a device for the continuous monitoring of atmospheric SO2 using UV fluorescence. The APSA-370 employs an proprietary, internal dry-method sampling device to achieve the highest levels of sensitivity and accuracy. The dry-method, due to its minimal maintenance requirements capability of continuous monitoring and instantaneous analysis of gas in its unaltered state, has been a preferred method for monitoring the atmospheric pollution.

 

 

Division: Ambient
Manufacturing Company: HORIBA, Ltd.
Base product: AP-370 Series

• UV-fluorescent detector resistant to moisture interference; Low range: 0-0.05 ppm F.S.
• Alternately to FDP measurements, the detector design is highly SO2 selective and requires no supplemental gas.
• Integral HC-cutter with a selective membrane eliminates interfering components.
• Incorporates a lamp intensity compensator.
• Uses a built-in inert PTFE sample inlet filter.

Related Applications

 

 

Principle

UV fluorescence (UVF)

Application

SO2 in ambient air

Range

Standard ranges: 0-0.05/0.1/0.2/0.5 ppm; auto range ~ manual range selectable; can be operated by remote switching.
Optional (measurable) ranges: 4 ranges selectable from 0-10 ppm, within 10 times range ratio;
auto range ~ manual range selectable; can be operated by remote switching.

Repeatability

±1.0% of F.S.

Linearity

±1.0% of F.S.

Sample gas flow rate

Approx. 0.7L/min

Indication

Measured value, range, alarm, maintenance screen

Alarms

During AIC, zero calibration error, span calibration error, temperature error in catalyzer, etc.

On-screen messages are available in four languages

English, German, French, and Japanese.

Input/output

• 0-1 V/0-10 V/4-20 mA, to be specified (2 systems: either (1) momentary value and integrated or (2) moving average value)
• Contact input/output
• RS-232C

Power

100/110/115/120/220/230/240 VAC, 50/60 Hz (to be specified)

Dimensions

430(W) x 550(D) x 221(H) mm

Mass

Approx. 19 kg.

scrollable
Real-Time Gas Measurement in Fuel Cells for Household and Commercial Use
Real-Time Gas Measurement in Fuel Cells for Household and Commercial Use
Monitoring of Airborne Molecular Contamination in Clean Room of Electronics Industry
Monitoring of Airborne Molecular Contamination in Clean Room of Electronics Industry

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

FTX-ONE-CL
FTX-ONE-CL

FTIR 배기 가스 분석기 희석 측정 타입

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR 배기가스 분석 측정 시스템 (직접 측정 방식)

IR-200
IR-200

Gas Monitor for Chamber Cleaning End Point Monitoring

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

MEXA-ONE
MEXA-ONE

배기 가스 측정 장치

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

레이저 분광 배기가스 측정 장치

OBS-ONE GS Unit
OBS-ONE GS Unit

차량 탑재형 배기가스 측정 장치

OBS-ONE IRLAM Unit
OBS-ONE IRLAM Unit

NH3/N2O 대응용 차량 탑재형 배기가스 측정 장치

Show More

Corporate