์ž๋™ ๊ต์ •/์„ธ์ • pH

์ž๋™ ๊ต์ • pH Meter AH-151์€ ์ž๋™์œผ๋กœ ์ „๊ทน์˜ ์•ฝ์•ก ์„ธ์ • ๋ฐ ํ‘œ์ค€์•ก ๊ต์ •๊ณผ pH ์ธก์ •์„ ํ†ตํ•ด ์œ ์ง€ ๋ณด์ˆ˜ ์ž‘์—…์„ ๋Œ€ํญ์ ์œผ๋กœ ๊ฐ์†Œ์‹œ์ผฐ์Šต๋‹ˆ๋‹ค.

๊ต์ •์•ก์„ ๋ถ„๋ฌดํ•˜๋Š” ๋ฐฉ์‹์„ ์ฑ„ํƒํ•˜์—ฌ ์‚ฌ์šฉ๋Ÿ‰์„ ์ค„์˜€์œผ๋ฉฐ, ์•ฝ์•ก๋„ ์˜ค์—ผ ์ƒํ™ฉ์— ๋”ฐ๋ผ ๋ถ„๋ฌด๋Ÿ‰ ์กฐ์ •์ด ๊ฐ€๋Šฅํ•˜๊ธฐ ๋•Œ๋ฌธ์— ๋น„์šฉ ์ ˆ๊ฐ์ด ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค.

์ •๊ธฐ์ ์ธ ์„ธ์ •/๊ต์ •์— ์˜ํ•ด ์‹ ๋ขฐํ•  ์ˆ˜ ์žˆ๋Š” pH ์ธก์ •์„ ์‹คํ˜„ํ•ฉ๋‹ˆ๋‹ค.

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

 โ— ์ปฌ๋Ÿฌ ํ„ฐ์น˜ ํŒจ๋„ ์•ก์ •์œผ๋กœ ๊ฐ„๋‹จํ•œ ์กฐ์ž‘
5.7์ธ์น˜ ํ„ฐ์น˜ ํŒจ๋„๋กœ ๊ฐ€์‹œ์„ฑ, ์กฐ์ž‘์„ฑ์ด ํ–ฅ์ƒ๋˜์—ˆ์œผ๋ฉฐ ์ž๋™ ๊ต์ •์‹œ ์ž๋™ ๊ทธ๋ž˜ํ”„ํ™”๋ฅผ ํ†ตํ•œ ์ „๊ทน ์ˆ˜๋ช… ํŒ๋ณ„์ด ์‰ฌ์›Œ์กŒ์Šต๋‹ˆ๋‹ค.

โ— pH 2์ฑ„๋„์— ์˜ํ•œ ๊ณต๊ฐ„ ์ ˆ์•ฝ
1๋Œ€์˜ ์žฅ์น˜์— pH ์ „๊ทน 2๊ฐœ๊ฐ€ ์ ‘์†ํ•  ์ˆ˜ ์žˆ์–ด์„œ ๊ณต๊ฐ„ ์ ˆ์•ฝ์ด ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค.

โ— ์œ ๋‹›ํ™”๋ฅผ ํ†ตํ•œ ๊ฐ„๋‹จํ•œ ์„ค์น˜
์œ ๋‹›ํ™”๋˜์–ด ์žˆ์–ด์„œ ์„ค์น˜๊ฐ€ ๋”์šฑ ๊ฐ„๋‹จํ•ฉ๋‹ˆ๋‹ค.

โ— ์œ ์ง€ ๋ณด์ˆ˜ ๋น„์šฉ ์ ˆ๊ฐ
๊ต์ •์•ก์„ ๋ถ„๋ฌดํ•ด์„œ ๊ต์ •์•ก์˜ ์‚ฌ์šฉ๋Ÿ‰์„ ์ฆ์˜€์Šต๋‹ˆ๋‹ค. ์•ฝ์•ก ์‚ฌ์šฉ๋Ÿ‰์„ ์˜ค์—ผ ์ •๋„์— ๋”ฐ๋ผ 50mL, 75mL, 100mL๋กœ ๋ถ„๋ฅ˜ํ–ˆ์œผ๋ฉฐ ์„ธ์ • 1ํšŒ๋‹น ๋ถ„๋ฌด๋Ÿ‰ ์„ ํƒ์ด ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค. (ํ‘œ์ค€์€ 50mL)

โ— ์ž๊ฐ€ ์ง„๋‹จ ๊ธฐ๋Šฅ
์ธก์ •์น˜ ์ด์ƒ์ด๋‚˜ ์„ผ์„œ ์—ดํ™”๋“ฑ์˜ ์ž๊ฐ€ ์ง„๋‹จ ๊ธฐ๋Šฅ์ด ์žˆ์–ด์„œ ์ „๊ทน์ด๋‚˜ ์žฅ๋น„์˜ ์ด์ƒ ์‹œ ์‹ ์†ํ•œ ๋Œ€์‘์„ ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. 

 

Product name

pH meter with automatic calibration function

Type

AH-151-CH (dip type), -CF (flow-through type), -FK (water sampling type)

Measuring method

Glass electrode method

Measuring range

pH: 0 to 14 Resolution: 0.01 pH

Temperature: 0 to 100ยฐC Resolution: 0.1 degree C

Display unit

Touch panel (TFT color LCD)

Repeatability

pH: within ยฑ0.02 pH, Temperature: ยฑ0.3ยฐC (Equivalent input)

Linearity

pH: within ยฑ0.03 pH, Temperature: ยฑ0.3ยฐC (Equivalent input)

Transmission output

Number of output points: 2, Output form: 4 to 20 mA DC input/output insulation type, Load resistance: Maximum 900 ฮฉ Output range 1: pH: Can be arbitrarily set within the measuring range

Output range 2: Temperature: Can be arbitrarily set within the range of -10 to 110ยฐC

Hold function: Can be arbitrarily set by selecting from โ€œlast value hold,โ€ โ€œany value hold,โ€ and โ€œwithout holdโ€

Contact output

Number of output points: 9 and 1 (abnormality alarm), Output form: No-voltage contact output,

Alarm details: Calibration errors (asymmetric potential abnormality, sensitivity abnormality, response time abnormality), electrode abnormalities (glass response membrane crack, short

circuiting of temperature sensor, disconnection of temperature sensor), abnormalities of converter (CPU abnormality, ADC abnormality, memory abnormality), shortage of cleaning solution, shortage of calibration solution

Cleaning interval

0.1 to 168.0 hours, Month, day and time of start of next cleaning can be set, Cleaning time: Approx. 2 minutes (default setting)

Calibration interval

1 to 999 hours, Month, day and time of start of next calibration can be set, Calibration time: Approx. 5 minutes (default setting when pH electrode is new)

Contact input

Number of input points: 3, Contact: No-voltage โ€œaโ€ contact for open collector, Contact function: External commands for cleaning performance (automatic cleaning start, automatic calibration start, stand-by commands)

Communication capability

RS-485 two-wire system, Input/output insulation type (not insulated from transmission output)

Combined electrode

Glass electrode 6108

Calibration method

Automatic calibration (lift-up type calibration with standard solution spray) or manual calibration

Cleaning method

Lift-up type cleaning with cleaning solution

Self-check

Calibration error, Electrode check, System error

Sample conditions

Pressure: Atmospheric pressure, Temperature: -5 to 80ยฐC, Flow velocity: 2 m/sec or less, Flow rate: 10 L/min or less (only for flow-through type), Conductivity: 10 mS/m (100 ฮผS/cm)

pH standard solution

Two solutions (pH7 and pH4 or pH9), Consumption: Approx. 30 to 40 mL/min (max. 200 mL/calibration), Capacity: PE tank 3 L (calibration approx. 15 to 50 times possible)

Cleaning chemical

HCI: less than 5 to 10%, Consumption: Approx. 50 mL/cleaning (approx. 75,100 mL/cleaning, adjustable)  Capacity: PE tank 20 L (cleaning approx. 300 times possible, using 50 mL each time

Water supply

Water quality: Tap water equivalent (industrial water possible), Pressure: 0.2 to 0.75 MPa, Consumption: 10 to 20 L/cleaning, calibration one time (in case of default setting for cleaning time)

Air supply

Air quality: Instrument air, Pressure: 0.3 to 0.7 MPa, Consumption: 10 to 15 L/min

Inlet

Supply water: Rc1/2, Air: Rc1/4

Cable gland

8 cable glands for ฯ†7 to ฯ†12 (without cable gland, ฯ†21.5 hole)

Operating temperature range

0 to 50ยฐC (no condensation)

Power supply

Voltage range: 100 to 240V AC ยฑ10%, 50/60 Hz, Power consumption: 100V AC, approx. 20 W during steady state and approx. 35 W during auto-calibration

Structure

Outdoor setting type: JIS C0920 explosion/splash-proof type (IP54 equivalent), Material of control unit case: SPCC (coated with melamine-based epoxy resin), Metal fittings: SUS304, Stand: SUS304

Mass

Operation unit & pole stand: Approx. 60 kg, Metal fittings: Approx. 3 kg, Lifting unit (dip type): Approx. 1.5 kg (except for dip-type holder