There is a local version available of this page. Change to the local version?
United States

VA-5000 / VA-5000WM Series

Multi-Component Gas Analyzer VA-5000 Series

Multi-Component Gas Analyzer

The Multi-Component Gas Analyzer VA-5000 Series is an all-round gas analyzer that satisfies measurement needs as required for environmental monitoring, energy development support, quality controls, and as a continuous emission monitoring system (CEMS). The VA-5000 Series Gas Analyzer can be configured with up to 4 detector modules within a single case. Many combinations of sensor modules with a wide selection of ranges allows this series of analyzers to be used for a variety of applications.

The Multi-Component Gas Analyzer is available as a 19-inch panel mount version (VA-5000) and as a wall mounted type analyzer (VA-5000WM) that enables to install in a limited installation space.

The optional VS-5000 Sample Gas Conditioning System is designed to support the VA-5000 Analyzer by proving the optimal sample conditions for measurement.

Division: Process Gas
Manufacturing Company: HORIBA, Ltd.

Product Features

Gas analyzer for Various Applications

  • Simultaneous measurement of up to four gas components:
    • CO: Carbon monoxide
    • CO2: Carbon dioxide
    • CH4: Methane
    • N2O: Nitrous oxide
    • NO: Nitric oxide
    • SO2: Sulfur dioxide
    • NH3: Ammonia
    • NOx: nitric oxide and nitrogen dioxide
    • O2: Oxygen
    • Siloxane
  • Auto pressure compensation provides stable measurements by compensating for barometric pressure changes
  • Employs a thermostatically controlled gas flow sensor to increase accuracy of measurements.
     

Ease of Use

  • A 5.7 inch LCD touchscreen provides analyzer information measurement status, trend graphs, diagnostics and analyzer settings
  • Detector modules can be added or replaced quickly
  • A front panel USB allows instrument instant settings to be logged in addition to sample data

          
     

Additional Features of the VA-5000 Gas Analyzer

  • Auto-calibration
  • Blowback control
  • Self-diagnosis
  • Data logging
  • Analyzer configuration settings
  • Multiple analog and digital outputs (option)
     

VA-5000 Series Sample Gas Conditioning System

  • Designed to support the VA-5000 Series Analyzer
  • Convenient 19-inch rack mount configuration
  • Integrates pumps, coolers, filters, flow controls, NOx converters, etc., within a single case

     

Related Industries

Related Applications

Specifications of the VA-5000 / VA-5000WM Multi-Component Gas Analyzer

Measurement principleNDIRCLAMagnetopneumaticGalvanic cellZirconiaParamagnetic
PerformanceLinearityStandard±1.0% F.S.
Option±2.0% F.S.(range ratio 1:20)-----
Response time30 sec or less (T90), 40 sec or less (Td+T90); single component*145 sec (Td+T90)
Warm-up time60 min (90 min for SO2)60 min60 min40 min20 min120 min
Flow rateStandard0.5L/min0.3L/min0.5L/min0.5L/min0.5L/min0.5L/min
Option1.0L/min*2----1.0L/min*2
CommunicationEthernet (ModbusTM/TCP)
Data storageOptionUSB memory
Input/Output (option)AnalogInputMaximum 4ch, 0-16 mA / 4-20 mA / 0-20 mA or 0-1 V isolated
OutputMaximum 8ch, 0-16 mA / 4-20 mA / 0-20 mA or 0-1 V isolated, Current output: load resistance < 750Ω, Voltage output: input impedance > 100k Ω
DigitalInputMaximum 16ch isolated, Open voltage: 24 V, Short-circuit current 10mA
Maximum load resistance < 50 Ω, Minimum pulse width: 0.5 sec
OutputMaximum 16ch isolated, Maximum voltage DC 30 V, Maximum current 1A
Minimum voltage DC 0.1 V, Minimum current 0.1 mA
Sample conditionAmbient temperature, dust free, H2O less than 5°C saturation, Pressure 0 to 490 Pa
Other: Shall contain no corrosive gas, combustible gas, and explosive gas.
Gas connectionsInlet and outlet - 6 mm/4 mm PTFE: a single gas inlet is provided standard; the gas flows sequentially from one module to the next; as an option separate gas inlets can be provided for each module
Gas tubingPTFE; stainless steel optional
JointSample Inlet: Rc 1/8(φ6/φ4mm PTFE joint), Exhaust: φ6/φ4mm PTFE joint
Air Inlet: Rc 1/8(φ6/φ4mm PTFE joint); installed CLA. CLA: Exhaust: φ6/φ4mm PTFE joint; installed CLA,
MPA Outlet: φ6/φ4mm PTFE joint; installed MPA, Zero gas Outlet: φ6/φ4mm PTFE joint; installed MPA
InstallationTemperature 0-45°C, Humidity 90% (No condensation), Altitude Max 3000m (combination with only NDIR), (combination with Zirconia, Galvani, MPA, and CLA: max 2000m), No fluctuation of backpressure
Protection degreeEquivalent to IP20
Power100-240 V AC (±10%, maximum voltage 250 VAC), 50/60 Hz (±1.0%), Consumption: 100 to 350 VA
Display5.7-inch touch screen
CaseVA-5000: 19-inch panel mount / VA-5000WM: Mounted on wall
Exterior dimensionsVA-5000: 430 (W) × 380 (D) × 132 (H) mm / Approx. 17 (W) × 15 (D) × 5.2 (H) in
Deozonator unit for CLA: 111 (W) × 95 (D) × 100 (H) mm / Approx. 4.4 (W) × 3.7 (D) × 3.9 (H) in *protrusions excluded
VA-5000WM: 424 (W) × 206 (D) × 484 (H) mm / Approx. 17 (W) x 8 (D) x 19 (H) in *protrusions excluded
MassVA-5000: 7-18kg, Approx. 15-40lb / VA-5000WM: 14-24kg, Approx. 31-53lb
scrollable

*1 When single component: flow rate is 0.5L/min (CLA: 0.3L/min)
*2 Available when all components are NDIR and PMA

See full Specifications including Dimensional Outlines of VA-5000/WM Analyzer and VS-5000 Sampling Unit (PDF)

 

Specifications of the VS-5000 Sampling Unit

ModelVS-5001VS-5002VS-5003VS-5004
Applicable principlesNDIR, Zirconia, Galvanic cell, PMANDIR, Zirconia, Galvanic cell, MPA, PMANDIR, Zirconia, Galvanic cell, CLA, PMANDIR、Zircoia, Galvanic cell, MPA, CLA, PMA
Form19 inch panel mount
Sampling method5°C dry sampling
MaterialsSUS, PP, PVC, PVDF, PTFE, FKM, CR, Glass
Flow rate1.5~5.0 L/min
Sample supply0.5 L/min x 2 systems*10.3L/min x 1system
Power100~240 V AC (±10%, maximum voltage 250V AC), 50/60 Hz (±1%)
Power consumption150 VA200 VA
JointSample inlet: φ8/φ6 mm PTFE joint, Sample outlet: φ6/φ4 mm PTFE joint
Air outlet: φ6/φ4 mm PTFE joint, MPA inlet: φ6/φ4 mm PTFE joint
Regulator: φ6/φ4 mm PTFE joint, Calibration inlet: RC1/8(φ6/φ4mm PTFE joint)
Bypass outlet/Exhaust/Drain outlet: φ8mm hose end
Sample gasAmbient temperature, Dust: less than 0.1mg/m3, H2O: less than 60°C saturation with drain pot (Approx. 25% H2O), Pressure: ±980 Pa, SO3: less than 50ppm, NO2: less than 6ppm*2 , (Corrosive gas, flammable gas and explosive gas are not included)
Dimension430 (W) x 550 (D) x 221 (H) mm / Approx. 17 (W) x 22 (D) x 8.7 (H) in (protrusions excluded)
Mass14kg / 31lb16kg / 35lb19kg / 42lb20kg / 44lb
scrollable

*1 Environmental temperature needs to be less than 35°C. If it's over 35°C, please consult HORIBA.
*2 When the sample gas includes more than 6ppm NO2, it needs to use optional NOX converter.

See full Specifications including Dimensional Outlines of VA-5000/WM Analyzer and VS-5000 Sampling Unit (PDF)

Real-Time Gas Measurement in Fuel Cells for Household and Commercial Use
Real-Time Gas Measurement in Fuel Cells for Household and Commercial Use
Real-time Measurement of Generated Gas from Safety Testing of Rechargeable Batteries
Real-time Measurement of Generated Gas from Safety Testing of Rechargeable Batteries
Nitrous Oxide Monitoring for Greenhouse Gas Reduction
Nitrous Oxide Monitoring for Greenhouse Gas Reduction
Quality Control in Medical Oxygen Gas Production and Verification
Quality Control in Medical Oxygen Gas Production and Verification
Continuous Monitoring of Sulfide Off-Flavors in Beverage Production
Continuous Monitoring of Sulfide Off-Flavors in Beverage Production

Show More

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

FTX-ONE-CL
FTX-ONE-CL

FTIR 배기 가스 분석기 희석 측정 타입

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR 배기가스 분석 측정 시스템 (직접 측정 방식)

IR-200
IR-200

Gas Monitor for Chamber Cleaning End Point Monitoring

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

MEXA-ONE
MEXA-ONE

배기 가스 측정 장치

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

레이저 분광 배기가스 측정 장치

OBS-ONE GS Unit
OBS-ONE GS Unit

차량 탑재형 배기가스 측정 장치

OBS-ONE IRLAM Unit
OBS-ONE IRLAM Unit

NH3/N2O 대응용 차량 탑재형 배기가스 측정 장치

Show More

EMGA-Expert
EMGA-Expert

산소/질소/수소 분석기

EMGA-Pro
EMGA-Pro

산소/질소/수소 분석기

EMIA-Expert
EMIA-Expert

탄소/황 분석기

EMIA-Pro
EMIA-Pro

탄소/유황 분석기

EMIA-Step
EMIA-Step

탄소/황 분석기 (인덕션 퍼니스 타입)

ENDA-7000 Series
ENDA-7000 Series

굴뚝 배출가스 분석장치

IR-200
IR-200

Gas Monitor for Chamber Cleaning End Point Monitoring

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

LO-300
LO-300

레이저 스캔 오일 필름 검출기

MEXA-ONE
MEXA-ONE

배기 가스 측정 장치

OBS-ONE GS Unit
OBS-ONE GS Unit

차량 탑재형 배기가스 측정 장치

OBS-ONE IRLAM Unit
OBS-ONE IRLAM Unit

NH3/N2O 대응용 차량 탑재형 배기가스 측정 장치

OCMA-500
OCMA-500

폐수 오일 측정기

OCMA-550
OCMA-550

오일 농도 측정기

Show More