There is a local version available of this page. Change to the local version?
United States

IT-480 series

High-Accuracy Infrared Thermometers [Stationary type]

Industry Leading* High Accuracy Thermometer

IT-480 series are compact, stationary type infrared thermometers with industry-leading* accuracy, which enables measurement without damaging the object.
These infrared thermometers are suitable for industrial applications such as temperature control of various product lines, devices and plants.
Also, by connecting USB to a personal computer (PC) equipped with Windows®, IT-480 series can be widely used for laboratory and R&D.
IT-480 Data Acquisition Software is required to connect PC to IT-480 series. This software can be downloaded free of cost.

▶ Thermometer Application Examples

*Resuts of 2024 in-house study

Division: Thermometer
Manufacturing Company: HORIBA, Ltd.

Our IT-480 series and IT-545 series are registered to Sustainable Technology Promotion Platform (STePP)of United Nations Industrial Development Organization (UNIDO) Investment and Technology Promotion Office, Tokyo (ITPO Tokyo)

(URL: http://www.unido.or.jp/en/activities/technology_transfer/technology_db/)

<Features>

  • High precision: Industry’s highest precision standard thermometer.
  • Traceability: Adjustment/Calibration according to the Japanese national standards.
  • Product conformity according to various country standards: CE, WEEE/RoHs, FCC, KC, laser pointer related (PSC, FDA)
  • Application software: Provided for free of cost
     

▶ Non-contact, non-destructive system allows measurement without damaging the products whether stationary, rotating or moving.
▶ Industry-leading high accuracy and real-time response.
▶ A wide measurement range. -50°C to 1000°C (IT-480F/480P)
▶ Compact, lightweight design allows installation in various devices and production lines.
▶ Allows flexible use. For R&D, experiments, confirmation before the installation of IT-480 etc.
    Easy to set and use anywhere.
    ・USB bus powered type, which requires no external power supply.
    ・Available to mount on the camera tripods.
    Use of Data Acquisition Software (downloadable free of cost)
    ・Up to 8 units of IT-480 can be connected to a Windows® PC by USB cable.
    ・Easy to setup by Windows® PC, and collects temperature data

<Software Screen example-Device Setup>

<Software screen example-Data acquisition>

<Software>

IT-480 Data Acquisition Software "IT-480 Data Acquisition" is software dedicated to the radiation thermometer IT-480 series. Check/Change of Various settings, operation check and data acquisition are available for IT-480 connected to a personal computer via USB with "IT-480 Data Acquisition".
This IT-480 Data Acquisition software is freely downloadable.
Many other items, other than this software are also downloadable.

*To use IT-480 series without this software current output: 4 mA to 20 mA is also available.

Software requirements

• This software functions on PC or tablets installed with either the 32-bit or 64-bit version of Windows 7, Windows 8, Windows 8.1, and Windows 10.
• At least 1 GB of hard disk space is required to install this software.
• A screen resolution of at least 1280 dots X 800 dots (100% scaling ratio) is recommended.

Function

This software can be used to execute the following functions:
• Checking and changing settings
• Auto emissivity setting
• Current output test
• Measurement data collection (maximum of 8 units can be connected)
General-purpose communication software can also be used.

Downloadable items:

  • Instruction Manual for the IT-480
  • Data Acquisition Software "IT - 480 Data Acquisition"
    • 32 bit.zip
    • 64 bit.zip
    • User Manual for the IT-480 Data Acquisition
  • Virtual COM port driver for IT-480
    • driver.zip

    Serial communication with IT-480 is available with communication software such as "Tera Term" or a program created by a customer by installing the virtual COM port driver for IT-480 on the personal computer.
    Check/Change of Various settings and measurement value acquisition for IT-480 are available with serial communication.
    When only IT - 480 data collection software "IT - 480 Data Acquisition" is used, Installation of the virtual COM port driver is not required.

    • Reference Manual for the IT-480 Virtual COM Port Driver

    This software works on personal computers or tablets equipped with Windows 7, Windows 8, Windows 8.1, Windows 10 (32 bit, 64 bit). Operation check is done at factory.
    It does not guarantee the operation on all devices.

    Download

 

Related Industries

■IT-480S, IT-480L

Type Micro-spot type Spot type
Model IT-480S IT-480L
Spectral response 8μm to14μm
Measured temperature range -50℃ to 500℃
Output USB (resolution = 0.1℃)
Current (4 mA to 20 mA, resolution =0.24μA, non-insulated)
Currnent output range -50℃ to 500℃ (factory setting 0℃ to 500℃)
Accuracy 〔USB Output〕
Within ±(-8%rdg+1)℃[-50℃ to 0℃]
Within ±1℃[ 0℃ to 200℃]
Within ±0.5%rdg℃[200℃ to 500℃]
〔Current Output〕
Difference from USB data is within ±(0.1% output range )℃
Repeatability Within 0.5℃
Response Time Current output 0.14 s or less
(95% response, moving average count is 1.)
Measurement diameter φ3 mm/ distance 30 mm φ8 mm/ distance 100 mm
Temperature drift Within ±0.5℃/℃[-50℃ to 0℃]
Within ±0.25℃/℃[0℃ to 500℃]
Emissivity Factory setting: 0.950
(Setting range is 0.100 to 1.999.)
Ambient temperature / humidity Temperature: 0°C to 55°C
Humidity: 35% to 85% (No condensation)
Power supply USB bus power /12 V DC to 24 V DC
Power consumption 30 mA or less (at 24 V DC)
Material of the body case Aluminum
Mass Approx. 95 g
(Body only. Excluding cable and metal brackets)
Sight Setting gauge
scrollable

■IT-480N, IT-480W, IT-480F, IT-480P

Type General purpose type Narrow view type
Model IT-480N / IT-480W*1 IT-480F / IT-480P*1
Spectral response 8μm to 14μm
Measured temperature range -50℃ to 500℃ -50℃ to 1000℃
Output USB (resolution = 0.1℃)
 Current (4 mA to 20 mA, resolution =0.24μA, non-insulated)
Currnent output range -50℃ to 500℃ (factory setting 0℃ to 500℃) -50℃ to 1000℃ (factory setting 0℃ to 500℃)
Accuracy 〔USB Output〕
Within ±(-8%rdg+1)℃
 [-50℃ to 0℃]
Within ±1℃
 [ 0℃ to 200℃]
Within ±0.5%rdg℃
 [200℃ to 500℃]
〔Current Output〕
Difference from USB data is within ±(0.1% output range )℃
〔USB Output〕
Within ±(-8%rdg+1)℃
 [-50℃ to 0℃]
Within ±1℃
 [ 0℃ to 200℃]
Within ±0.5%rdg℃
 [200℃ to 1000℃]
〔Current Output〕
Difference from USB data is within ±(0.1% output range )℃
Repeatability Within 0.5℃ Within 1℃[ -50℃ to 0℃]
Within 0.5℃[ 0℃ to 500℃]
Within 1℃[ 500℃ to 1000℃]
Response Time Current output 0.14 s or less
(95% response, moving average count is 1.)
Measurement diameter φ72 mm/ distance 1000 mm φ35 mm/ distance 1000 mm
Temperature drift Within ±0.5℃/℃
 [-50℃ to 0℃]
Within ±0.25℃/℃
 [0℃ to 500℃]
Within ±0.5℃/℃
 [-50℃ to 0℃]
Within ±0.25℃/℃
 [0℃ to 500℃]
Within ±0.5℃/℃
 [500℃ to 1000℃]
Emissivity Factory setting: 0.950
(Setting range is 0.100 to 1.999.)
Ambient temperature / humidity Temperature: 0°C to 55°C
Humidity: 35% to 85% (No condensation)
Power supply USB bus power / 12 V DC to 24 V DC
Power consumption 30 mA or less (at 24 V DC, laser: OFF)
40 mA or less (at 24 V DC, laser: ON)
Material of the body case Aluminum
Mass Approx. 95 g
(Body only. Excluding cable and metal brackets)
Approx. 115 g
(Body only. Excluding cable and metal brackets)
Sight Laser (Class 1)*1
scrollable

*1) IT-480W and IT-480P are not equipped with the laser pointer

Improving the Safety of Transport by Crane Using Thermometer
Improving the Safety of Transport by Crane Using Thermometer

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

CS-620F
CS-620F

광섬유형 고온 인산 농도 모니터

CS-900
CS-900

비접촉 화학물질 농도 모니터

HC-200F
HC-200F

현장설치형 불소이온측정기(4-Wire Transmission)

HC-300F
HC-300F

현장설치형 불소이온측정기(2-Wire Transmission)

HD-200
HD-200

현장설치형 용존산소측정기(4-Wire Transmission), 멤브레인형)

HD-200FL (Four-Wire Transmission, 광학식)
HD-200FL (Four-Wire Transmission, 광학식)

현장 설치형 용존 산소 측정기

HD-300
HD-300

현장설치형 용존산소측정기(2-Wire Transmission), 멤브레인 형)

HD-480
HD-480

용존산소측정기(4-Wire Transmission), 멤브레인 형)

HD-960L
HD-960L

저농도 용존 산소 모니터

HD-960LR
HD-960LR

용존 산소 농도 모니터

HE-200C
HE-200C

현장설치형 전기전도도계(4-Wire Transmission, 저농도용)

HE-200H
HE-200H

현장설치형 전기전도도계(4-Wire Transmission, 고농도용)

HE-200R
HE-200R

현장 설치형 전기저항계(4-Wire Transmission)

HE-300C
HE-300C

현장 설치형 전기전도도계 (2-Wire Transmission, 저농도용)

HE-300C-IS ( 방폭형 )
HE-300C-IS ( 방폭형 )

방폭형 설치 타입 COND meter ( Low concentrtion )

HE-300R
HE-300R

현장 설치형 전기저항계(2-Wire Transmission)

HE-480C
HE-480C

패널 장착형 전도도계(4-Wire Transmission, 저농도용)

HE-480C-GC
HE-480C-GC

카본 센서 전도도계 (저농도형)

HE-480H
HE-480H

패널 장착형 전도도계(4-Wire Transmission,저농도용)

HE-480H-DC24V
HE-480H-DC24V

판넬 장착형 전도도계(4-wire Transmitter , 고전도도용)

HE-480R
HE-480R

패널 장착형 저항계(4-Wire Transmission)

HE-960CA
HE-960CA

구연산 모니터

HE-960CW
HE-960CW

패널 장착형 전도도계(4-Wire Transmission, 2채널)

HE-960H-KOH
HE-960H-KOH

KOH 모니터

HE-960H-TM-S
HE-960H-TM-S

고정밀 TMAH 농도 모니터

HE-960HC
HE-960HC

카본 센서 전도도계 (고농도형)

HE-960HI
HE-960HI

패널 장착형 전도도계(4-Wire Transmission, 광역용)

HE-960LC
HE-960LC

카본 센서 전도도계

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

평탄 카본 센서 전도도계

HE-960RW
HE-960RW

패널 장착형 저항계(4-Wire Transmission, 2채널)

HE-960RW-GC(W)
HE-960RW-GC(W)

2-채널 저항률계

HO-480
HO-480

패널 장착형 ORP 미터 (4-Wire Transmission)

HP-200 (Four-Wire Transmission)
HP-200 (Four-Wire Transmission)

현장 설치형 pH Meter

HP-300
HP-300

현장 설치형 pH미터 (2-Wire Transmission)

HP-480
HP-480

패널 장착형 pH미터 (4-Wire Transmission)

HP-480PL
HP-480PL

패널 장착형 pH 미터(4-Wire Transmission, 펄스 비례 제어)

HP-480TP
HP-480TP

패널 장착형 pH 미터(4-Wire Transmission, 산업용 시분할 비례제어)

HP-960FTP
HP-960FTP

패널 장착형 pH 미터(4-Wire Transmission, 4 포인트 알람, 시분할 비례 제어)

HR-200
HR-200

현장 설치형 잔류염소 측정기 (4-Wire Transmission, Water flow beads)

HR-200RT
HR-200RT

현장 설치형 잔류 염소 측정기 (4-Wire Transmission, Rotating Type)

HR-480
HR-480

잔류 염소 측정기 (4-Wire Transmission)

LAQUA PH210
LAQUA PH210

Handheld pH/ORP/Temperature Meter

TW-100
TW-100

자동 수질 측정장치

TW-150
TW-150

Online Water Quality Monitor (공정 수질 측정 시스템)

U-50 Series
U-50 Series

다항목 수질 측정기

UP-100
UP-100

마이크로 볼륨 pH 모니터

Show More

Corporate
English
한국어