Explosion-proof Gas Analyzer

HORIBA’s 51 Series of explosion-proof analyzers provide safe, reliable and accurate measurements when analyzing flammable gases or operating in explosive environments. The 51 Series complies with Japanese explosion-proof certification (JPEx). The 51 Series explosion-proof analyzers infrared allow for the measurement of CO, CO2, CH4 and other organic gases. The TCA-51 uses a thermal conductivity detector for H2 measurements and the MPA-51 and PMA-51 models integrate magneto-pneumatic and paramagnetic detectors for O2 measurements.

Division: Process Gas
Manufacturing Company: HORIBA, Ltd.
  • Explosion-proof Models for Flammable and Explosive Classified Areas
    The 51 Series is approved for use explosive and flammable atmospheres in Japan, which complies with Japanese explosion-proof certification (JPEx).
     
  • Self diagnosis function
    To provide stable gas analyses, a self-diagnosis function is activated when an abnormal condition is detected. A management function when enacted shows the records of calibration factors and controls auto calibration.
     
  • Reliable analysis
    A correction or compensating detector mitigates interferences of gases that interfere with the gas being measured
     
  • LED Display
    The highly visible 51 Series LED display allows operators to easily view the analyzer’s status

 

 

Model EIA-51dEIA-51pTIA-51dTIA-51p
Type of protectionExd Ⅱ B+H2T4Expx Ⅱ T4XExd Ⅱ B+H2T4Expx Ⅱ T4X
Frameproof enclosures  
Pressurized apparatus  
Measuring principleNon-Dispersive Infrared Absorption Method (NDIR)
ComponentCO, CO2, CH4, etc.*1
Measurement rangeMinimum range0 to 0.11 vol% (Depends on the component)0 to 50 ppm (Depends on the component)
Maximam range0 to 100 vol% (Depends on the component)0 to 2000 ppm (Depends on the component)
Optional100-90 to 50 vol%  (Depends on the component)0-20 to within less than 50 ppm (Depends on the component)
Range Ratio
PerformanceRepeatabilityStandard rangeZero : ±0.5% of full scaleZero : ±0.5% of full scale
Span : ±0.5% of full scaleSpan : ±0.5% of full scale
Optional rangeZero : ±0.5% of full scaleZero : ±1.0% of full scale
Span : ±0.5% of full scaleSpan : ±1.0% of full scale
Linearity±1.0% of full scale
Drift*2Standard rangeZero : ±2.0% of full scale/week
Span : ±2.0% of full scale/week
Optional rangeVaries by specification
Response time
(from inlet of analyzer)
T90 within 20 seconds
T90 within 40 seconds (TIA optional range)
Sample gas ConditionGas compositionFlameproof enclosuresO2 : 21% or less, no mist, no dust
The hazardous must be equivalent or less with electrical apparatus group Ⅱ B, gas and vapor-air mixture corresponding to temperature code T4, and Hydrogen-air mixture.
Pressurized apparatusO2 : 21% or less, no mist, no dust
The ignition temperature must be equivalent or less with electrical apparatus of gas and vapor-air mixture corresponding to temperature code T4.
PressureOver 1.98 kPa
Flow rateApprox. 500 mL/min.
TemperatureAmbient temperature
ExhaustAtmosphere pressure
Materials in contract with sample gasSUS304, SUS316, FKM, CaF2, Au, etc.
Calibration methodStandard : Manual correction, Option : Automatic correction
Analog outputOutput content / Output specifications1 concentration output channel / DC 4 to 20 mA (DC 0 to 16 mA / 0 to 20 mA, DC 0 to 1 V / 0 to 5 V / 1 to 5 V / 0 to 10 V optional)
Alarm settingArbitrary setting is available with span range from -10% to +110% of output for current and voltage. Negative output values set to zero.
Contact Input-output (option)6 channels
Digital connection (option)InterfaceRS-485
ProtocolModbus-RTU
Communication speedSelected from 19200 bps / 9600 bps / 4800 bps / 2400 bps / 1200 bps
Environment conditionsLocationIndoors
Operational Temperature-5 to 40 °C (away from direct sunlight and radiant heat)
Humidity90% or less
VibrationAvoid large vibration sources (less than 100 Hz; 0.3 m/s2)
UtilityProtective gas for Pressurized apparatus compositionGas composition : N2, Gas pressure : 196 to 690 kPa,  Gas flow rate : 10 L/min. (when purging), 500 mL/min. (when operating) Dew Point : -30°C Saturated or less
scrollable

*1 Please consult HORIBA for measurement of the other components. *2 Guaranteed at normal ambient temp. ±5°C

 

■Recommended Measuring Ranges

 EIA-51d/51pTIA-51d/51p
Min. RangeMax. RangeMin. RangeMax. Range
CO0 to 0.21%0 to 100%0 to 50 ppm0 to 2000 ppm
CO20 to 0.11%0 to 100%0 to 50 ppm0 to 1000 ppm
CH40 to 0.21%0 to 100%0 to 50 ppm0 to 2000 ppm
C3O80 to 0.051%0 to 100%0 to 50 ppm0 to 500 ppm
NO0 to 0.21%0 to 100%0 to 100 ppm0 to 2000 ppm
SO20 to 0.051%0 to 100%0 to 100 ppm0 to 500 ppm
scrollable

Please consult HORIBA for applications other than those listed above.

 

ModelTCA-51dTCA-51pMPA-51dMPA-51pPMA-51d
Type of protectionExd Ⅱ B+H2T4Expxd Ⅱ T4XExd Ⅱ B+H2T4Expx Ⅱ T4XExd Ⅱ B+H2T4
Frameproof enclosures  
Pressurized apparatus   
Measuring principleThermal Conductivity Detector Method (TCD)Paramagnetic (magneto-pneumatic type)Paramagnetic (dumb-bell type)
ComponentH2O2
Measurement rangeMinimum range0 to 10 vol%0 to 5 vol%
Maximam range0 to 100 vol%0 to 25 vol%
Optional0-1 to within less than 10 vol% 100-90 to 50 vol%0-1 to within less than 5 vol%
Range RatioMax.1:25 Max.4 rangeMax.1: 5
PerformanceRepeatabilityStandard rangeZero : ±1.0% of full scaleZero : ±0.5% of full scaleZero : ±0.1 vol% O2
Span : ±1.0% of full scaleSpan : ±0.5% of full scaleSpan : ±0.1 vol% O2
Optional rangeZero : ±1.0% of full scaleZero : ±1.0% of full scale
Span : ±1.0% of full scaleSpan : ±1.0% of full scale
Linearity±1.0% of full scale
Drift*2Standard rangeZero : ±2.0% of full scale/weekZero : ±1.0% of full scale/weekZero : ±0.05% vol% O2/week
Span : ±2.0% of full scale/weekSpan : ±2.0% of full scale/weekSpan : ±0.05% vol% O2/week
Optional rangeVaries by specificationZero : ±1.0% of full scale/weekVaries by specification
Span : ±3.0% of full scale/week
Response time
(from inlet of analyzer)
T90 within 20 seconds
Sample gas ConditionGas compositionFlameproof enclosuresO2 : 21% or less, no mist, no dust
The hazardous must be equivalent or less with electrical apparatus group Ⅱ B, gas and vapor-air mixture corresponding to temperature code T4, and Hydrogen-air mixture.
Pressurized apparatusO2: 21% or less, no mist, no dust
The hazardous must be equivalent or less with electrical apparatus of group Ⅱ C gas and vapor-air mixture corresponding to temperature code T4.
O2: 21% or less, no mist, no dust
The ignition temperature must be quivalent or less with electrical apparatus of gas and vapor-air mixture corresponding to temperature code T4.
PressureOver 1.98 kPa14.7 to 24.5 kPaOver 1.98 kPa
Flow rateApprox. 500 mL/min.Approx. 1.5 L/minApprox. 300 mL/min
TemperatureAmbient temperature
ExhaustAtmosphere pressure
Materials in contract with sample gasSUS304, SUS316, FKM, glass, SiO2, AUSUS304, SUS316, FKMSUS304, SUS316, Pt, glass, FKM
Calibration methodStandard : Manual correction, Option : Automatic correction
Analog outputOutput content / Output specifications1 concentration output channel / DC 4 to 20 mA (DC 0 to 16 mA / 0 to 20 mA, DC 0 to 1 V / 0 to 5 V / 1 to 5 V / 0 to 10 V optional)
Alarm settingArbitrary setting is available with span range from -10% to +110% of output for current and voltage. Negative output values set to zero.
Contact Input-output (option)6 channels
Digital connection (option)InterfaceRS-485
ProtocolModbus-RTU
Communication speedSelected from 19200 bps / 9600 bps / 4800 bps / 2400 bps / 1200 bps
Environment conditionsLocationIndoors
Operational Temperature-5 to 40°C (away from direct sunlight and radiant heat)
Humidity90% or less
VibrationAvoid large vibration sources (less than 100 Hz; 0.3 m/s2)
UtilityProtective gas for Pressurized apparatus compositionGas composition : N2, Gas pressure : 196 to 690 kPa, Gas flow rate : 10 L/min. (when purging), 500 mL/min. (when operating) Dew Point : -30°C Saturated or less
scrollable

*1 Please consult HORIBA for measurement of the other components. *2 Guaranteed at normal ambient temp. ±5°C

 

■System configuration

Recommended Measuring Ranges

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

SLFA-6000
SLFA-6000

X선 형광 유황 분석기

FTX-ONE-CL
FTX-ONE-CL

FTIR 배기 가스 분석기 희석 측정 타입

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR 배기가스 분석 측정 시스템 (직접 측정 방식)

IR-200
IR-200

Gas Monitor for Chamber Cleaning End Point Monitoring

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

MEXA-ONE
MEXA-ONE

배기 가스 측정 장치

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

레이저 분광 배기가스 측정 장치

OBS-ONE GS Unit
OBS-ONE GS Unit

차량 탑재형 배기가스 측정 장치

OBS-ONE IRLAM Unit
OBS-ONE IRLAM Unit

NH3/N2O 대응용 차량 탑재형 배기가스 측정 장치

Show More

EMGA-Expert
EMGA-Expert

산소/질소/수소 분석기

EMGA-Pro
EMGA-Pro

산소/질소/수소 분석기

EMIA-Expert
EMIA-Expert

탄소/황 분석기

EMIA-Pro
EMIA-Pro

탄소/유황 분석기

EMIA-Step
EMIA-Step

탄소/황 분석기 (인덕션 퍼니스 타입)

ENDA-7000 Series
ENDA-7000 Series

굴뚝 배출가스 분석장치

IR-200
IR-200

Gas Monitor for Chamber Cleaning End Point Monitoring

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

LO-300
LO-300

레이저 스캔 오일 필름 검출기

MEXA-ONE
MEXA-ONE

배기 가스 측정 장치

OBS-ONE GS Unit
OBS-ONE GS Unit

차량 탑재형 배기가스 측정 장치

OBS-ONE IRLAM Unit
OBS-ONE IRLAM Unit

NH3/N2O 대응용 차량 탑재형 배기가스 측정 장치

OCMA-500
OCMA-500

폐수 오일 측정기

OCMA-550
OCMA-550

오일 농도 측정기

Show More

Corporate