There is a local version available of this page. Change to the local version?
United States

APHA-370

Hydrocarbon Monitor / THC Analyser

Our APHA-370 measuring device is a continuously operating analyzer for determining Total hydrocarbons (THC), CH4  and non-CH4  in the ambient air. Further applications exist in various areas of process and trace analysis. The Horiba measuring device APHA-370 is a flame ionization detector that uses the "cross flow modulation principle".  Measuring gas and reference gas are fed alternately to the measuring cuvette.  The measurement gas serves as the reference gas. in which the THC concentration was eliminated. This guarantees low-maintenance operation and extremely stable measurements. The measuring device is almost interference-free and has an internal measuring gas pump. The burner air is generated from the ambient air and fed to the detector.

Division: Ambient
Manufacturing Company: HORIBA, Ltd.
Base product: AP-370 Series

• Selective combustion flame ionization detector measures total hydrocarbon (THC), NMHC and CH4  simultaneously.
• Single detector eliminates zero drift; Low range: 0-5 ppmC F.S.
• Integrates relative sensitivity correction for CH4  and NMHC.
• Integrates a reference and combustion air generator, NMHC cutter and sample pump.
• Requires H2 as fuel gas for the FID.

Applications:

Monitoring of Airborne Molecular Contamination in Clean Room of Electronics Industry

 

Measuring principle

Flame ionization detector(FID)

 

Applications

THC Measurement in ambient air

 

Measuring range

• standard : 0-5/ 10/ 25/ 50 ppm

Can be controlled manually, automatically or externally
Optional: measuring range extension 0-100 ppm.

• max. measuring range ratio = 1:10

 

Limit of detection

0,022 ppm (3δ)

 

Repeatability

±1.0 % of full scale

 

Linearity

±1.0 % of full scale

 

flow rate

ca. 0,5 l/min

 

Response time (T90)

< 60 sec. (lowest range)

 

Display

Concentration in ppm (ppb) or mg (µg)/m3

 

Compensation

pressure and temperatur

 

Languages

German, English, French, Japanese

 

Interfaces

RS-232C (Gesytec / HORIBA Protocol)

 

Options

• Ethernet Interface

• Analooutput 0-1/10 V or 0(4) - 20 mA

• Long-term data storage

• Calibration units

• Further options on request

 

Ambient temperature

0-40°C

 

Power supply

240 VAC, 50 Hz, ca. 170 VA

 

Dimensions

430(W) x 550(D) x 221(H) mm (5HE)

 

weight

Approx. 33 Kg.

scrollable
Monitoring of Airborne Molecular Contamination in Clean Room of Electronics Industry
Monitoring of Airborne Molecular Contamination in Clean Room of Electronics Industry

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

FTX-ONE-CL
FTX-ONE-CL

FTIR 배기 가스 분석기 희석 측정 타입

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR 배기가스 분석 측정 시스템 (직접 측정 방식)

IR-200
IR-200

Gas Monitor for Chamber Cleaning End Point Monitoring

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

MEXA-ONE
MEXA-ONE

배기 가스 측정 장치

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

레이저 분광 배기가스 측정 장치

OBS-ONE GS Unit
OBS-ONE GS Unit

차량 탑재형 배기가스 측정 장치

OBS-ONE IRLAM Unit
OBS-ONE IRLAM Unit

NH3/N2O 대응용 차량 탑재형 배기가스 측정 장치

Show More

Corporate