A highly advanced analyzer solves the mysteries of the nano-world. A single device analyzes the three parameters that characterize nanoparticles: particle size, zeta potential, and molecular weight.

Nanotechnology research and development is a continuously evolving effort to control substances at the atomic and molecular level in order to achieve new and better materials and products. The miniaturization of components – that is, control at the nano-level – is necessary to achieve faster, higher-performance devices and functions and to reduce energy consumption. Nanotechnology has come to play a key role in wide-ranging fields that affect our daily lives, including food, cosmetics, and the life sciences.

Clear and simple multi-parameter analysis of nanoparticles!

Three analyzers in a single compact body deliver high-sensitivity, high-accuracy analysis of each measurement parameter.

Segment: Scientific
Manufacturing Company: HORIBA, Ltd.

Particle Size Measurement Range 0.3 nm to 10 µm

The SZ-100V2 Series measures particle size and particle distribution width by dynamic light scattering (DLS).
Analysis across a wide range of sample concentrations: Measurement of samples ranging from low ppm-order concentrations to high-concentration samples in double-digit percentages is possible. Accepts commercially available sampling cells. Analysis of small-volume samples is also possible.

Zeta Potential Measurement – 500 to + 500 mV

Analysis of sample volumes as small as 100 μL using HORIBA-developed microelectrophoresis cells. Use the value of zeta potential to predict and control dispersion stability. High zeta potential magnitudes indicate a stable dispersion, useful for formulation work.

Molecular weight 1 × 103 to 2 × 107 Da

Absolute molecular weight (Mw) and the second virial coefficient (A2) are obtained by performing static light scattering measurement as a function of sample concentration and preparing Debye plots.

The SZ-100V2 Series applies sophisticated intelligence and learning capability to rapidly determine nanoparticle properties!

  • Since the SZ-100V2 Series analyzer covers a wide sample concentration measurement range, sample dilution and other preprocessing is nearly eliminated.
  • The use of a dual optical system enables measurement of high-concentration samples such as slurry and ink pigments as well as low-concentration proteins and polymers.
  • A single device analyzes the three parameters that characterize nanoparticles: particle size, zeta potential, and molecular weight.
  • HORIBA-developed cells for zeta potential measurement prevent sample contamination. Simple analysis by means of ultra micro-volume dedicated cells (volume as low as 100 μL). Suitable for analysis of dilute samples.
  • HORIBA-developed electrode for zeta potential cell made from carbon material, the material is not corroded by high salt samples such as saline.

Product video

Video Player is loading.
Current Time 0:00
Duration 2:41
Loaded: 0%
Stream Type LIVE
Remaining Time 2:41
 
1x
    • Chapters
    • descriptions off, selected
    • subtitles off, selected
    • en (Main), selected

      ­SZ-100-S2 Measurement Specifications

      Model

      SZ-100-S2 (particle size and molecular weight measurement only)

      Measurement principles

      Particle size measurement: Dynamic Light Scattering
      Molecular weight measurement: Debye plot method (static scattered light intensity)

      Measurement range

      Particle size: 0.3 nm to 10 μm
      Molecular weight: 1000 to 2 x 107 Da (Debye plot)
                                   540 to 2 x 107 Da (MHS Equation)*1

      Maximum sample concentration

      40 wt%*2

      Particle size measurement accuracy

      Measurement accuracy of ±2% for NIST traceable polystyrene latex
      100 nm spheres (not including variation in the standard particles themselves)

      Measurement angles

      90° and 173° (automatic or manual selection)

      Cells

      Cuvettes

      Measurement time

      Approx. 2 min. under ordinary conditions
      (from the start of measurement to the display of results for particle size measurement)

      Required sample volume

      Minimum volume of 12 μL*3 to 1000 μL (differs depending on cell material)

      Usable liquids

      Water, ethanol, organic solvents

      scrollable

      *1: Mark-Howink-Sakurada Equation, depending on sample.
      *2: Depending on sample.
      *3: F Micro-cell.

       

      SZ-100-Z2 Measurement Specifications
      (Particle size and molecular weight measurement specifications are the same as for the SZ-100-S2.)

      Model

      SZ-100-Z2 (with zeta potential measurement unit)

      Measurement principle

      Zeta potential measurement: Laser Doppler electrophoresis

      Measurement range

      -500 to +500 mV

      Size range suitable for measurement

      Minimum 2.0 nm, Maximum 100 μm*4

      Measurement conductivity range

      0 to 20 S/m*5

      Maximum sample concentration

      40 wt%*6

      Cells

      Dedicated cell with electrodes

      Measurement time

      Approx. 2 min. under ordinary conditions

      Required sample volume

      100 μL

      Carrier fluids

      Water

      scrollable

      *4: Depending on sample.
      *5: Recommended sample conductivity range: 0 to 2 S/m.
      *6: Depending on sample.

       

      Analyzer Specifications (SZ-100-S2 and SZ-100-Z2)

      Measuring unit optical system

      Light source: Diode pumped frequency doubled laser (532 nm, S2 / Z2 10 mW, HS2 / HZ2 100 mW)
      Detectors: Photomultiplier tubes (PMT)

      Laser classification

      Class I

      Operating temperature and humidity

      15 - 35 °C, RH 85% or less (no condensing)

      Holder temperature control temperature settings

      0 - 90 °C (up to 70 °C for cells with electrodes and plastic cells)

      Purging

      Dry gas purge port tube connection is possible.

      Power supply

      AC 100 - 240 V, 50/60 Hz, 150 VA

      Dimensions

      528 (W) x 385 (D) x 273 (H) mm (excluding protrusions)

      Weight

      25 kg

      Personal computer

      Windows computer with one available USB port

      Interface

      USB 2.0 (between measuring unit and PC)

      OS

      Windows® 10 64-bit and Windows® 11 64-bit

      scrollable

      Dimensions (mm)

       


      Accessories

      Particle size cells

       Cell nameMin volumeSolvent
      ADisposable cell1.2 mLAqueous
      BSemi-micro cell500 µLAqueous, non-aqueous
      CGlass cell1.2 mLAqueous, non-aqueous
      DSemi-micro disposable cell600 µLAqueous
      ECell with lid1.2 mLAqueous, non-aqueous
      FMicro cell (90° only)12 µLAqueous, non-aqueous
      GSub-micro cell200 µLAqueous, non-aqueous
      HFlow cell100 µLAqueous, non-aqueous
      scrollable

       

      Zeta potential cells

      Zeta potential cells
      Disposable zeta potential cells for aqueous measurements. Box of 20 Volume = 100 µL

      Disposable zeta potential cells
      Non-aquoeus zeta potential cell. Volume = 100 µL

      Zeta Potential of Proteins
      Zeta Potential of Proteins
      This application note presents data from the SZ-100 using cells with unique, patented carbon coated electrodes that facilitate zeta potential measurements of proteins.
      Zeta Potential of Polyelectrolytes
      Zeta Potential of Polyelectrolytes
      The zeta potential of polyethylenimine, PEI, is measured as a function of polymer concentration with the SZ-100 Nanoparticle Analyzer. Charged polymers, that is, polyelectrolytes can be analyzed with the SZ-100.
      Zeta Potential of Clay for Wastewater Treatment
      Zeta Potential of Clay for Wastewater Treatment
      In this note, the effect of coagulant choice and concentration on the treatment of suspended clays is analyzed.
      DLS vs. Diffraction of Flavor Emulsions
      DLS vs. Diffraction of Flavor Emulsions
      The particle size distribution of many flavor emulsions has a substantial effect on their performance. Particle size distribution can affect mouth feel, appearance, and emulsion stability.
      Wastewater Treatment Optimization with Zeta Potential
      Wastewater Treatment Optimization with Zeta Potential
      Suspended solids are a common impurity in wastewater from industrial and mining operations. In order for water clarity, the suspended solids are often allowed to settle. The duration of these processes is a strong function of the particle size. Thus, if particles can be made to aggregate, the settling process is shorter and the treatment operation is faster and less expensive.
      Sizing Silica Particles by DLS
      Sizing Silica Particles by DLS
      In this application note, the particle sizes of two different silica dispersions are analyzed to demonstrate the utility of the SZ-100 for both suppliers and users of such materials.
      Nanoparticle Analysis
      Nanoparticle Analysis
      Nanotechnology is extremely diverse, ranging from novel extensions of conventional device physics, to completely new approaches based upon molecular self-assembly and to developing new materials with dimensions on the nanoscale. Materials reduced to the nanoscale can show different properties compared to what they exhibit on a macroscale, enabling unique applications.
      Metal Nanoparticle Size and Surface Charge (Zeta Potential)
      Metal Nanoparticle Size and Surface Charge (Zeta Potential)
      Metal nanoparticles (also known as colloidal metal) have been around for a very long time. Both pure metal and metal oxide colloids are used in a wide variety of applications including catalysts, ferrofluids, biological markers, and many others. Particle size and zeta potential of these suspensions are critical physical parameters that affect functionality and stability.
      Protein Aggregation and Size Analysis
      Protein Aggregation and Size Analysis
      The study of protein aggregation encompasses a broad range of interactions and mechanisms. The LA-960 laser diffraction particle size analyzer possesses the unique ability to measure from 10 nanometers to 5 millimeters, accurately detecting the aggregates and, in some cases, the primary protein size.
      Titanium Dioxide Particle Size
      Titanium Dioxide Particle Size
      Titanium Dioxide (TiO2) is a pigment used in paints and many other applications. The particle size of titanium dioxide directly impacts its performance in numerous applications, necessitating the measurement and control of this important property.
      Viruses and Virus-Like Particles
      Viruses and Virus-Like Particles
      A virus particle consists of several parts including the genetic material (DNA or RNA), a protein coat that protects these genes, and in some cases an envelope of lipids that surrounds the protein coat when they are outside a cell.
      Particle Analysis for Cosmetics
      Particle Analysis for Cosmetics
      Many cosmetic products include particulate material or emulsions. Some examples of cosmetic products consisting of or including particulates include facial powders, moisturizers, and lipstick. The particle size distribution of these components effects appearance, stability, and protection.

      Show More

      Request for Information

      Do you have any questions or requests? Use this form to contact our specialists.

      * These fields are mandatory.

      Product accessories

      Related products

      Partica LA-960V2
      Partica LA-960V2

      Laser Scattering Particle Size Distribution Analyzer

      ViewSizer 3000
      ViewSizer 3000

      Simultaneous Multi-Laser Nanoparticle Tracking Analysis (NTA)

      ANALYSETTE 28 ImageSizer*
      ANALYSETTE 28 ImageSizer*

      Dynamic Image Analysis

      Eyecon2™*
      Eyecon2™*

      Direct Imaging Particle Analyzer

      Partica CENTRIFUGE
      Partica CENTRIFUGE

      Centrifugal Nanoparticle Analyzer

      Partica LA-960V2
      Partica LA-960V2

      Laser Scattering Particle Size Distribution Analyzer

      Partica mini LA-350
      Partica mini LA-350

      Laser Scattering Particle Size Distribution Analyzer

      PD10
      PD10

      Reticle / Mask Particle Detection System

      RP-1
      RP-1

      Reticle/Mask Particle Remover

      SA-9600 Series
      SA-9600 Series

      BET Flowing Gas Surface Area Analyzers

      SA-9650 Series
      SA-9650 Series

      BET Surface Area Analyzers

      ViewSizer 3000
      ViewSizer 3000

      Simultaneous Multi-Laser Nanoparticle Tracking Analysis (NTA)

      Show More

      PD10
      PD10

      Reticle / Mask Particle Detection System

      Corporate