United States

Field-installation type calcium ion meter

HC-200CA

For treatment of hydrofluoric acid wastewater from semiconductor production.

Contributes to reduction of chemical usage in the wastewater treatment process by continuously monitoring calcium ion concentration in the tank. Running costs and risk of scale generation are reduced by optimizing chemical usage, thereby contributing to stable plant operation.

 

Ca2+

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Stable measurement

Using the ion selective electrode has made possible the stable monitoring of calcium ion concentration.

Lower running costs

Reduction of chemical consumption can be expected by controlling chemicals according to wastewater treatment status.

Reduced environmental impact

Contributes to the reduction of industrial waste by reducing the risk of sludge and scale generation due to excess calcium ions.

■Indication converter specifications

Transmitter modelHC-200CA
Sensor modelCA-2000:Calcium ion sensor
Sensor chip model7695: Calcium ion chip, 7211: Reference chip
Measurement rangeCalcium ion concentration:10 to 4000 mg/L (display range: 0 to 4000 mg/L)
Temperature:0 to 40 °C (display range: -10 to 110 °C)
Measurement conditionspH:5 to 11
SampleWater in top clear layer of CaF2 sedimentation tank in fluoride acid wastewater treatment of semiconductor manufacturing facility.
ConcentrationCa2+: 200 to 600 mg/L,
SO42-: 200 to 700 mg/L, pH:5 to 11
Temperature25 to 40 °C
Conductivity10 to 20 mS/cm
If used in other applications, it may cause unstable measurement values, shorten electrode life, etc. Please contact HORIBA.
Available range options100.0, 1000, 4000 mg/L
Display resolutionCalcium ion concentration:0.1 mg/L: 0.0 to 100.0 mg/L, 1 mg/L: 0 to 1000 mg/L, 10 mg/L: 0 to 4000 mg/L
※It depends on the set range.
Temperature:0.1 °C
RepeatabilityCalcium ion concentration:±10% of reading (standard solution)
Temperature:±0.3 °C (equivalent input)
Temperature compensationCompatible temperature element:Platinum resistor: 1 kΩ (0 °C)
Temperature measurement range:0 to 40 °C
Temperature calibration:1 point calibration for comparison with the reference thermometer
CalibrationStandard solution calibration (2 points)
Select 1 to 10 mg/L, 10 to 100 mg/L, or 100 to 1000 mg/L
AdjustmentSample adjustment using manual analysis (1 point), standard curve input function (linear function)
Self-checkCalibration error, sensor diagnosis error, transmitter error
Transmission output3 points 4 to 20 mA DC, input/output isolation type  Maximum load resistance 900 Ω
Output1:Calcium ion concentration: Arbitrary setting within the measurement range is possible.
Output2:Temperature: Arbitrary setting within the range from -10 to 110 °C is possible.
Error output:Provided with burnout function (selectable from 3.8 mA and 21 mA for setting)
Hold function:Selectable from the latest value hold and the preset value hold
Contact output3 points No-voltage contact output Relay contact, SPST (1a), SPDT (1c)
Signal R1, R2:Selectable from among the upper limit alarm, lower limit alarm, during transmission output hold,
             and cleaning output (closed at alarm operation, open under normal conditions and in a power-off state)
             FAIL:Error alarms for values outside the measurement range and self-check output can be set.
             Delay time: 0 to 600 seconds
Cleaning output1 point Voltage contact output (connection power supply voltage output) Relay contact, SPDT (1a)
Contact function:Solenoid valve for cleaning control
Contact input1 point No-voltage "a" contact for open collector
Contact function:Select from the external input of the cleaning operation and HOLD input transmission output
Communication functionRS-485 2 wire system, isolated from the input circuit
Not isolated from transmission circuit
Operation temperature range-20 to 55 °C (no freezing)
Power supplyRated power supply voltage:AC 100 to 240 V ±10% 50/60 Hz, Power consumption:25 VA(max)
StructureProtection class:IP65, Installation method:50 A pole-mounted or wall-mounted,
Material of case:Aluminum alloy, Material of hood and the mounting brackets:SUS304
MassMain frame:Approx. 3.5 kg  Hood,mounting bracket: Approx. 1 kg
Compliance standardCE marking, FCC Rules
scrollable

■Probe specifications

Sensor unit modelCA-2000
Sample condition0 to 40 °C (no freezing)
Measurement depth0 to 10 m
Wetted materialSUS316, FKM, PVC
MassApprox. 2.7 kg (including 10 m cable)
Combination holderDrop-in type
Combination cleaning unitUltrasonic wave, air jet
scrollable

■Consumables

ModelPart name
7695Calcium ion chip
7211Reference chip
L-CA-1010 mg/L of calibration solution
L-CA-100100 mg/L of calibration solution
L-CA-10001000 mg/L of calibration solution
C-7211Junction cap
scrollable

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.