There is a local version available of this page. Change to the local version?
United States

PFS-ONE

PFS-ONE - Particulate Filter Management System
PFS-ONE (GMC-ONE)
PFS-ONE - Weighing of Emission Particles
PFS-ONE (Generation 3)

Particulate Filter Management System

New legislative regulations and the demand for greater flexibility and accuracy have led to the development of HORIBA’s Particulate Weighing Solution – PFS-ONE.

The automated filter weighing solution for measuring PM2.5 and PM10 includes weighing processes and complete filter handling in compliance with the latest regulations and standards. The PFS-ONE consists of HORIBA application software running on a standard PC and includes a filter weighing robot and a cleanroom workbench as part of the solution.

The PFS-ONE is available in two versions: GMC-ONE, featuring a METTLER TOLEDO robot, and Generation 3, equipped with a DENSO-COBOTTA robot. Both comply with UN GTR No. 24 and DIN EN 12341:202310 and are suitable for the mobility industry and environmental measurements. It can be used as a stand-alone installation or an integrated laboratory module and can be tailored to custom needs.

Features

  • Process-orientated automated weighing solution
  • Process profiles adjustable to different applications and use cases
  • Documentation of filter lifecycle, progress, time control and limit violations
  • Upload of all data to external storage systems
  • Compliance with current legislations for the automotive and environmental industry
     

Key Benefits

  • Very high accuracy due to automatic weighing process of the robot
  • Compliance with current legislations, regulations and standards:
    • ECE-R83 and ECE-R49
    • EPA1065, CARB and WLTP
    • UN GTR No. 24
    • DIN EN 12341:202310
  • Time savings during test operations due to adjustable process profiles to different applications and use cases (Certification, COP, Environmental, ...)
  • Ready-to-print reports of weighing results and process data
  • Upload of results to external storage systems in various file formats
  • Documentation of filter lifecycle, progress, time control and limit violations
  • The basic component PFS-ONE Control Unit can be combined in different ways and also adapted in a running hardware environment for example with an existing balance or cleanroom work bench
  • Manual or automated weighing
  • Stand-alone installation or fully integrated laboratory module
  • Easy integration of existing devices


Specifications

PFS-ONE is available in two versions, GMC-ONE and Generation 3. Please compare the specifications of both versions in the following tables:
 

PFS-ONE Control Unit

 GMC-ONEGeneration 3
Hardwarestandard desktop PC
2 network cards
min. 8 GB memorymin. 16 GB memory
quad core CPU or better (Intel i7 or comparable)
TFT monitor 22”
barcode reader and printer (optional)
Softwareapplication software for PFS-ONE Control Unit
Windows 10Windows 10 or Windows 11
.NET Framework 4.6
scrollable


PFS-ONE Chambers

 GMC-ONEGeneration 3
Versionmanual with pass-through or automated prepared for PFS-ONE Robot
upgradable from manual to automatic
Legislation complianceECE-R83, ECE-R49, EPA1065, CARB, WLTP
Regulation complianceUN GTR No. 24
Standard ComplianceDIN EN 12341:2023-10
Cleanroom classificationISO 4 (ISO 14644-1), equiv. class 10 (FED STD 209E)
Temperature22 °C ± 1 °C / IPE 20 °C ± 1 °C
Humidity controlmobility applications 45 ± 8 % / environmental applications 45 ± 3 %
Dewpoint mirror9.5 °C ± 1 C
InterfaceTCP/IP network protocol (climatic data from integrated weather statiion and health status), USB (for data storage)
Balance isolationintegrated vibration isolated graniteintegrated vibration isolated marble table
Footprint (max.)W 1370 x H 1995 x D 960 (mm)W 500 x H 1900 x D 800 (mm)
Working dimensionsW 930 x H 660 x 650 (mm)W 1000x H 690 x 700 (mm)
Power supply200-240 VAC (L1/N/PE), 50 - 60 Hz, max. power consumption 5,5 kW
Weightapprox. 500 kgapprox. 400 kg
scrollable


PFS-ONE Robot

 GMC-ONEGeneration 3
Filter diameter standard47 mm25 mm & 37 mm
Reference-filter positionuser-defined
Footprint (max.)W 780 x H 680 x D 650 (mm)arm length 342.5 mm (TCP 385 mm)
Throughputup to 900 weighings a dayup to 1000 weighings a day
Filter holder included153 pieces220 pieces
External calibration weight50, 100 , 200 or 400 mg
TechnologyMETTLER TOLEDO XYZ rack with stepper motorDENSO COBOTTA six-axis robot
Power supply100-230 V / 50-60 Hz
scrollable


PFS-ONE Balance

 GMC-ONEGeneration 3
Balance Readability0.1 μg
Repeatability with filter (SD)*0.25 μg
Repeatability with filter typical (SD)*0.15 μg
Repeatability stainless steel test weight≤ 0.2 μg
Built-in balance adjustmentautomatic
Maximum load2.1 g
Electrical weighing range0 - 2.1 g
Linearity1 μg
Miscellaneousultra-micro filter balance
anti-static kit
-camera
scrollable

* SD = standard deviation, with conductive filter media such as Pall TX40 without ionizer.

Particle Measurement in the Sub-23nm Range
Particle Measurement in the Sub-23nm Range
Concerns exist that advances in modern engine technology may contribute to large portions of solid particles at sizes smaller than 23nm. The EU Joint Research Center has confirmed this concern in several investigations.

Solicitud de Información

Tiene alguna pregunta o solicitud? Utilice este formulario para ponerse en contacto con nuestros especialistas.

* Estos campos son obligatorios.

Related products

MDLT-ONE
MDLT-ONE

Micro Dilution Tunnel

MEXA-2000SPCS series
MEXA-2000SPCS series

Solid Particle Counting System

MEXA-ONE
MEXA-ONE

Motor Exhaust Gas Analyzer

OBS-ONE PN Unit
OBS-ONE PN Unit

On-board Emissions Measurement System

OBS-ONE SPN10 Unit
OBS-ONE SPN10 Unit

On-board SPN10 measurement for real-world

Show More