SLFA-60

X-ray Fluorescence Sulfur-in-Oil Analyzer

Safer, Simpler and Swift: Effortless Sulfur Analysis in Oil

  • Ultra-low Detection Limit: It measures sulfur concentrations of 20 ppm or less, and can measure higher sulfur concentrations of crude and shale oil markets, up to 9.9999 wt%.
  • Portability at Its Best: Take it anywhere with ease - only 9 kg weight with small footprint.
  • Enhanced Safety: In addition to the thorough X-ray leakage test performed at the factory, the key switch and shield shutter provide additional protection for the operator.
  • Simple Operation: After selecting the calibration curves and measurement conditions, or selecting the correct calibration curve using the "A" mode, simply press the "MEAS" button to start the measurement.

 

Measurable Oils
Petroleum products such as heavy oil, naphtha, crude oil, shale oil and diesel oil.

Compliant with Standards
ASTM D4294, ISO 8754, JIS K2541/B7995

IMO's 2020 GLOBAL SULFUR CAP Compliant
Read Application Note

Segment: Scientific
Manufacturing Company: HORIBA, Ltd.

Where can it be installed?

The SLFA-60 is a compact sulfur-in-oil analyzer based on energy-dispersive X-ray fluorescence (EDXRF) technology. It is portable and can be used on-board, thanks to its pump-free and LN2-free optics. The SLFA-60 series does not require a laptop or external printer, making it flexible to install in any location.

(Left) Placing a sample cell on the measurement position  (Right) Light weight and portable

 

How can I get data without operational computer and printer?

The SLFA-60 has an integrated large-screen display and touch buttons on the main unit, which makes it easier for users to operate the device intuitively. The buttons are covered with a resin sheet to prevent oil from adhering to the device and make it easier to keep it clean. The SLFA-60 also has an integrated printer that can print out all the necessary information on 80 mm wide paper.

 

How does it protect the device from oil leakage accident?

The SLFA-60 has a protective membrane under the sample cell. It protects the optics (detector and X-ray tube) from accidental sample leakage. The protective membrane is a single unit that is easy for the user to replace.

 

Is it safe from X-ray exposure?

The SLFA-60 has a two-tier safety system to prevent X-ray leakage: an X-ray shield, an interlock function, and a shutter function. The X-ray shield blocks X-rays from escaping the instrument. The interlock function prevents the X-ray tube from operating if the chamber lid is open. The shutter function closes over the X-ray port once the chamber lid is open, further preventing X-ray leakage. The SLFA-60 meets the requirements of IEC 61010-1, which specifies that the X-ray leakage rate must be under 5 µSv per hour. The SLFA-60 goes even further, with a design specification of under 1 µSv per hour. This means that the SLFA-60 is one of the safest X-ray fluorescence analyzers on the market.

Measurement PrincipleEnergy Dispersive X-ray Fluorescence Analysis Method (EDXRF)
Measurement SampleSulfur in Petroleum products such as heavy oil, naphtha, and crude oil, light oil
Measurement Range0 - 9.9999 %
Repeatability15 ppm or less (with a 1 % sulfur sample)
C/H Error Correction± 50 ppm or less per C/H (with a 1 % sulfur sample)
Lower Detection Limit20 ppm or less (three times the standard deviation with a 0 % sample)
Number of Calibration Curves5 lines × 3 sets (Total 15 lines)
Calibration Curve OrderLinear or quadratic (both automatic selection and manual settings available)
CalibrationCalibration made using calibration points: (5 - 20 points)
Sample Requirement4 - 10 mL
Measurement Time10 - 600 sec
Spectrum MeasurementEnergy Axis: 0 - 10 keV, spectrum analysis to verify instrument performances.
External OutputUSB connection with PC, USB memory

Ambient Conditions

Temperature+ 5°C ~ + 40°C (+ 41°F ~ + 104°F)
Humidity80% max relative humidity in temperature range + 5°C ~ + 30°C (+ 41°F ~ + 86°F).
Linear decrease to 50% relative humidity in temperature range + 31°C ~ + 40°C (+ 88°F ~ + 104°F).

Power and Housing

Power SupplyAC 100 - 240 V ± 10 %, 50/60 Hz
Power Consumption80 VA
Dimensions [W x D x H]230 x 400 x 140 mm (9 x 15.75 x 5.5 in.)
Weight9 kg (20 lbs.)
Cooling systemAir-cooling

Conformity Standards

ASTM D4294 (USA) · ISO 8754 · JIS K2541/B7995

Schematics

Sulfur monitoring in Marine Oil with the SLFA in a growing environmental protection context
Sulfur monitoring in Marine Oil with the SLFA in a growing environmental protection context
Monitoring of Sulfur in petroleum products is an important topic in the current environmental protection context. Indeed, during combustion, Sulfur will cause acid rains and particles emissions that induce environmental and health problems. If industries and vehicles emissions have been the main target of Sulfur emission control since few tens of year, the new target is the maritime navigation. In this domain, now, the level of Sulfur is regulated by the MARPOL (International convention) Annex VI. For this specific regulation, the technique and measuring range of our SLFA series is perfectly suitable to allow the fast and accurate determination of Sulfur in Marine oil. Our compact SLFA-60 can be used on board and the SLFA-6800, with its autosampler (eight positions), will enhance the productivity of the control laboratories.

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Related products

EMGA-921
EMGA-921

Hydrogen Analyzer

EMGA-Expert
EMGA-Expert

Oxygen/Nitrogen/Hydrogen Analyzer
(Flagship High-Accuracy Model)

EMGA-Pro
EMGA-Pro

Oxygen/Nitrogen Analyzer (Entry Model)

EMIA-Expert
EMIA-Expert

Carbon/Sulfur Analyzer
(Flagship High-Accuracy Model)

EMIA-Pro
EMIA-Pro

Carbon/Sulfur Analyzer (Entry Model)

EMIA-Step
EMIA-Step

Carbon/Sulfur Analyzer (Tubular Electric Resistance Heating Furnace Model)

MESA-7220V2
MESA-7220V2

X-ray Fluorescence Sulfur/Chlorine-in-oil Analyzer

SLFA-6000
SLFA-6000

X-ray Fluorescence Sulfur-in-Oil Analyzer

XPLORER-NS*
XPLORER-NS*

Total Nitrogen and Sulfur Analyzer

XPLORER-TX/TS*
XPLORER-TX/TS*

Total Halogen and Sulfur Analyzer

LO-300
LO-300

Laser scanning oil film detector

MESA-7220V2
MESA-7220V2

X-ray Fluorescence Sulfur/Chlorine-in-oil Analyzer

OCMA-500
OCMA-500

Oil content analyzer

OCMA-550
OCMA-550

Oil content analyzer

SLFA-20
SLFA-20

X-ray Fluorescence Sulfur-in-Oil Analyzer

SLFA-2100/2800
SLFA-2100/2800

X-ray Fluorescence Sulfur-in-Oil Analyzers

SLFA-6000
SLFA-6000

X-ray Fluorescence Sulfur-in-Oil Analyzer

X-5000*
X-5000*

Energy Dispersive X-ray Fluorescence Analyzer

XPLORER-NS*
XPLORER-NS*

Total Nitrogen and Sulfur Analyzer

XPLORER-TX/TS*
XPLORER-TX/TS*

Total Halogen and Sulfur Analyzer

XPLORER-V*
XPLORER-V*

Next Generation Total Nitrogen and Total Sulfur Analyzer

MESA-50
MESA-50

X-Ray Fluorescence Analyzer

MESA-50K
MESA-50K

X-Ray Fluorescence Analyzer

MESA-7220V2
MESA-7220V2

X-ray Fluorescence Sulfur/Chlorine-in-oil Analyzer

SLFA-20
SLFA-20

X-ray Fluorescence Sulfur-in-Oil Analyzer

SLFA-2100/2800
SLFA-2100/2800

X-ray Fluorescence Sulfur-in-Oil Analyzers

SLFA-6000
SLFA-6000

X-ray Fluorescence Sulfur-in-Oil Analyzer

X-5000*
X-5000*

Energy Dispersive X-ray Fluorescence Analyzer

XGT-9000
XGT-9000

X-ray Analytical Microscope (Micro-XRF)

XGT-9000SL
XGT-9000SL

X-ray Analytical Microscope
with a Super Large Chamber