Featured Video
A Superior Spectrometer Concept
The Future of Fluorescence
- Three-in-one Fluorescence and Absorbance Spectrometer
- UV-Vis-NIR Fluorescence Detection Wavelength Range from 250 to 1,100 nm
- Full 3-D Fluorescence EEM Acquisition in Less Than One Second
- Best in Class Fluorescence Sensitivity Specification of 6,000:1 RMS for Water Raman
- Automatic Correction for Primary and Secondary Inner Filter Effects (IFE)
- High Fidelity Molecular Fingerprinting with Unique A-TEEM™ (Absorbance-Transmittance Excitation Emission Matrix) Technology
- Millisecond CCD Detection of Entire Fluorescence Spectrum
Fluorescence and Absorbance in one Spectrometer!
Duetta can be used as a fluorometer, as a UV-Vis-NIR spectrometer to measure absorbance, or as an instrument that measures true molecular fingerprints, which require the acquisition of fluorescence and absorbance, correcting for IFE in real time.
Fluorescence in the Blink of an Eye!
Duetta’s ultra-fast, state-of-the-art CCD technology allows it to outperform, by orders of magnitude, any competitor using PMTs. It’s the fastest bench-top fluorometer in the world, and the only fluorometer that can acquire a full spectrum in less than 100 milliseconds! This state-of-the-art CCD technology also extends NIR wavelength detection to 1,100 nm, well beyond the limit of a standard PMT fluorometer.
Highest Fluorescence Sensitivity in its Class
Having the highest level of fluorescence sensitivity means that Duetta’s optimized design lets you measure lower concentrations of a sample, and provides better quality data.
EzSpec™ Touch-Screen Software!
Duetta debuts HORIBA’s new generation software interface with touch-screen utility, and a selection of Apps for routine analysis.
Watch how EzSpec software performs the Pass/Fail |
EzSpec Software obtains a concentration curve |
EzSpec Software executes a Protein A280 concentration |
EzSpec Software discovers Fluorescence profiles in about 60s |
A New Spectrometer Design
Fluorescence and Absorbance
Duetta’s two specialized sample detectors collect fluorescence at right angles to the excitation light, and absorbance straight through the sample.
Absolute Fluorescence Spectra with Real Time Inner Filter Effect (IFE) Correction
IFE limits the linearity of the fluorescence signal at higher sample concentrations due to primary and secondary re-absorption of fluorescence. Duetta’s unique design applies real time IFE correction to obtain absolute fluorescence spectra at higher sample concentrations.
CCDs Collect the Entire Emission Spectrum
Ergonomic, Hands Free, Sample Access
Duetta’s CCD detection takes a snapshot of the entire fluorescence emission spectrum from 250 to 1,100 nm. (So not only is it much faster but it also gives you much more information than the competition.)
Extended NIR Wavelength Range up to 1,100 nm
Near Infrared applications are growing rapidly, and Duetta is ready to meet the challenge with fluorescence detection from 250 to 1,100 nm, well beyond the reach of standard PMTs.
Emission from Neodymium Glass
NIR detection comparing Duetta with PMT.
Easy Lamp Cartridge Replacement Lamp
Lamp cartridges are pre-aligned at the factory, guaranteeing perfect alignment upon snap-in replacement. No tools or service are required.
Smart Sample Accessory Trays
Switching from one type of sample holder to another could not be easier.
Without any tools or cables, Duetta’s spill-proof sample accessory trays are identified by EzSpec software, enable electrical power for the appropriate module (e.g. 4-position Peltier holder), and read an enabled
sensor (e.g. temperature), if available.
Fully Automated Order Sorting Filters
Duetta includes excitation and emission cut off filters for automated elimination of second order grating effects, which otherwise interfere with the fluorescence signal of interest.
EEMs Acquired in Seconds
Excitation Emission Matrix (EEM) acquired in 1 second, shows no second order scattering.
EzSpec Software
Apps at your Fingertips
From the EzSpec launch screen, each Apps icon intuitively helps you see and select the analysis you want to perform with a simple point and touch.
Apps:
- Autonomous Acquisition
- Pass/Fail
- Build/Use a Concentration Curve
- Protein A280
EzSpec lets you see your recent method and data, and your personal favorites.
Widest Range of Spectroscopic Acquisition Modes:
- Fluorescence emission spectra plus Abs & IFE*
- Fluorescence excitation spectra plus Abs & IFE*
- Capture fluorescence value plus Abs & IFE*
- Fluorescence EEM plus Abs & IFE*
- Fluorescence kinetics (emission spectra* or single point intensities)
- Absorbance and % Transmittance (spectra or kinetics)
* Unique to Duetta
Acquire Menu
PDF Report Generator or Export:
- Includes data and results of fitting/processing
- Full method details
- 2D and 3D graphs
- Instrument and user identification information
- Customizable logo
- Optional and customizable signature fields
- Full data and method traceability
Accessories
Optional Sample Holder Trays
SampleSnap-WJ: Thermostated and Micro-Stirred Cuvette Sample Tray
Self-identifying thermostatable, water jacketed cuvette holder (1 cm) with magnetic microstir motor. Sample tray can be installed in seconds without the need of a tool, and provides power for micro-stirrer. Requires, but does not include, external water bath.
SampleSnap-1Pelt: Single Cuvette Peltier Holder Sample Tray
Self-identifying single cuvette Peltier holder (1 cm) for automated temperature control and ramping from -15 to +105 degrees Celsius, with magnetic micro-stirrer. Sample tray can be installed in seconds without the need of a tool, and provides power and control of the Peltier device, and reads temperature. Includes external water circulator for heat sink.
SampleSnap-4Pelt: Four Position Peltier Cuvette Sample Tray
Self-identifying four position Peltier holder (1 cm) for automated temperature control and ramping from -15 to +110 degrees Celsius, with magnetic micro-stirrers under all four positions. Sample tray can be installed in seconds without the need of a tool, and provides power and control of the Peltier device, and reads temperature. Includes external water circulator for heat sink.
SampleSnap-UNI: Universal Variable Angle Sample Tray
Self-identifying sample holder with 360 degree variable angle goniometer for empirical determination of optimum sample angle. Sample tray can be installed in seconds without need of a tool. Requires, but does not include, solid sample holder accessory (SampleSnap-SS), powder sample holder accessory (SampleSnap-PWD) or cuvette holder accessory (SampleSnap-VACVT).
Sample Accessories for SampleSnap-UNI Universal Variable Angle Sample Tray
- SampleSnap-SS: Solid Sample Accessory
Solid sample accessory for universal sample holder to be used with flat or solid samples such as thin films, cover slips, paper, gemstones and more. Requires, but does not include, SampleSnap-UNI. - SampleSnap-PWD: Powder Sample Accessory
Powder sample accessory for universal sample holder. Requires, but does not include, SampleSnap-UNI. - SampleSnap-VACVT: Variable Angle Cuvette Sample Accessory
Cuvette sample accessory for universal sample holder. Requires, but does not include, SampleSnap-UNI.
Additional Accessories
K-210: Six pack of windows for powdered sample holder
K-151: 10 mm quartz cuvette
LampSnap: Replacement Duetta light source assembly with pre-aligned xenon arc lamp
K-AFILTER: Replacement Duetta air intake filter
* Duetta includes a standard room temperature single cuvette sample holder tray.
Applications
Duetta supports applications in a wide variety of fields
- Chemistry
- Life Sciences
- Materials Research
- Food Science
- Earth Sciences
Chemistry/Photochemistry
Pyrene in a solution of A-B-A triblock copolymer micelles is solvated in the hydrophobic core solvent environment. 3D EEMs can be shown in contour, waterfall plot, or 2D overlay mode.
Biology and Biochemistry
BSA protein measured from 5° C to 60° C and the peak intensity and peak wavelength are plotted vs. temperature of the protein solution. Measured using the SampleSnap-4Pelt 4-position Peltier temperature-controlled cuvette holder.
Materials
Polymer Aggregation and Structure. Temperature dependent spectra showing polymer micellization.
Molecular Binding (FRET)
A. Kinetic spectral scans of native BSA protein with rapidly added ANS (3x10-6 M). Spectra taken every 100 ms after ANS addition. As ANS binds to native BSA, the BSA Trp emission decreases and the ANS emission increases as a result of FRET due to proximity of excited Trp and ANS.
B. Kinetic spectral scans of SDS-denatured BSA after addition of ANS. Much higher ANS concentration (4x10-5 M) is required to affect binding to enatured BSA; no FRET is observed due to increased distances between ANS and Trp.
Rare Earths
Emission spectra of a series of glass materials containing different lanthanides. Measured using the SampleSnap-Uni solid sample holder.
Protein Biophysics
Comparison of bovine serum albumin protein and the same protein denatured by sodium dodecylsulfate (SDS). The emission peak narrows and shifts 15 nm to the blue.
Pharmaceuticals
Quenching: Fluorescence monitoring of the titration of 1 M potassium iodide (KI) into a solution of 2-aminopyridine, a common small molecule drug pre-cursor.