Outline
Model | Standard type: MEXA-ONE-FT Euro VI compliance type: MEXA-ONE-FT-E |
Conformed standards | CE, FCC, KC |
Target components and ranges*1 | Maximum 28 components |
Applications | Emissions performance tests of various engines, evaluation of after-treatment systems, R&D for alcohol-based fuels, Certification of NH3emissions according to Euro VI |
Principle | Fourier transform infrared spectroscopy (FTIR) |
Outputs/Inputs | Monitoring on 17-inch LCD |
Sample line temperature | MEXA-ONE-FT: 113 ± 6ºC |
Sample gas flow rate | MEXA-ONE-FT: 4.0 ± 0.5 L/min MEXA-ONE-FT-E: 14 ± 1 L/min |
Operating environment | Ambient temperature: 15 to 35ºC |
System Configuration
Liquid nitrogen | Replenishing amount: approx. 500 ml (including evaporation) Duration: 10 hours or more (The dewar vacuum must be renewed annually) |
Power supply voltage | Any of the following power line voltages and frequencies (to be specified when ordering) ・ 100 ± 10 V AC, 50/60 ± 1 Hz, single phase ・ 110 ± 11 V AC, 50/60 ± 1 Hz, single phase ・ 115 ± 11.5 V AC, 50/60 ± 1 Hz, single phase ・ 120 ± 12 V AC, 60 ± 1 Hz, single phase ・ 200 ± 20 V AC, 50/60 ± 1 Hz, single phase ・ 220 ± 22 V AC, 50 ± 1 Hz, single phase ・ 230 (207~250) V AC, 50 ± 1 Hz, single phase ・ 240 (216~250) V AC, 50 ± 1 Hz, single phase |
Power requirements | Approx. 4.0 kVA as maximum, approx. 3.0 kVA at stable state |
Dimensions | 655 (W) x 855 (D) x 1970 (H) mm |
Mass | Approx. 460 kg |
Performance
Zero noise*2 | Less than 1.0% of full scale |
Response time*3 (t10-90) | MEXA-ONE-FT: 5 seconds or less when switching from N2 to 200 ppm CO. MEXA-ONE-FT-E: 5 seconds or less when switching from N2 to 200 ppm NH3 |
Repeatability *4 *5 | Within ±1.0% of full scale |
Zero drift/span drift*4 *5 | Within ±1.0% of full scale/8 hours |
Warm-up time | Less than 2 hours after turning on the main power |
Options
Sample line selector | 8 lines |
Analog output board | Analog output: 0-10V Max. 16 channels |
Host communication cable | LAN cable |
NH3 filter element | Silica fiber (φ19.6 mm x L90 mm) |
THC measurement | Principle: Heated flame ionization detection (HFID) Measurement range: from 0-10 ppmC to 0-60000 ppmC |
O2 measurement | Principle: Magnetopneumatic Detector (MPD) Measurement range: from 0-1 vol% to 0-25 vol% |
Automatic replenishing device for liquid nitrogen | Maximum storage amount: Approx. 12 L |
*1: To be specified when ordering.
*2: The zero noise is defined as the twofold standard deviation of the concentration reading.
*3: Using a sample probe (0.3 m), a heated filter and a heated pipe (6 m) without contamination of the sample line.
*4: Confirmed with 200 ppm CO, 500 ppm CH4 and 200 ppm C2H6.
*5: Span gas with more than 80% of the full scale concentration shall be used.